| 14. ERROR CODE TABLE | ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Code | Cause |
| Remedy | |
|
|
| 1. | Turn off the power and check that the feed mechanism is |
|
|
|
|
| normal and that the work clamp moves smoothly. |
|
| Feed and work clamp motor overcurrent | 2. | Check that connectors P2 and P5 on the sub P.C. board |
| |
|
| are properly connected. |
| ||
|
|
| 3. | Check that connector P22 on the main P.C. board and |
|
|
|
|
| connector P10 on the sub P.C. board are properly |
|
|
|
|
| connected. |
|
|
|
| 1. | Turn off the power and check if the zigzag mechanism |
|
| Zigzag motor overcurrent |
| moves smoothly. |
| |
| 2. | Check that connector P16 on the main P.C. board is |
| ||
|
|
|
| ||
|
|
|
| properly connected. |
|
|
|
| 1. | Return the treadle to the neutral position. |
|
| Treadle is depressed to step 2. | 2. | If an error still occurs after 1. is carried out, check that |
| |
|
| connector P7 on the main P.C. board is properly |
| ||
|
|
|
|
| |
|
|
|
| connected. |
|
|
|
| 1. | Return the treadle to the neutral position. |
|
|
|
| 2. | If the error still occurs after step 1 is carried out, adjust the |
|
| Treadle is depressed to step 1. |
| threshold value for memory switch No. 08 to a positive |
| |
|
| value. |
| ||
|
|
|
|
| |
|
|
| 3. | Check that connector P7 on the main P.C. board is |
|
|
|
|
| properly connected. |
|
|
|
| 1. | Return the treadle to the neutral position. |
|
|
|
| 2. | If the error still occurs after step 1 is carried out, adjust the |
|
| Treadle is depressed backward. |
| threshold value for memory switch No. 07 to a negative |
| |
|
| value. |
| ||
|
|
|
|
| |
|
|
| 3. | Check that connector P7 on the main P.C. board is |
|
|
|
|
| properly connected. |
|
|
|
| 1. | Turn off the power and check that the inside of the control |
|
| Control circuit board heat sink is |
| box is being properly ventilated. |
| |
| overheating. | 2. Clean the filter of the air intake and the cooling fan. |
| ||
|
|
| |||
|
|
|
| (Remove dust.) |
|
|
|
| 1. | Turn off the power and clean the inside air circulation |
|
|
|
|
| cooling fan. (Remove dust.) |
|
| Inside air circulation fan problem | 2. | Check that connectors P13 and P20 on the main P.C. |
| |
|
| board are properly connected. |
| ||
|
|
|
|
| |
|
|
| 3. | Check that connectors CN2, CN3 and CN4 on the |
|
|
|
|
| power supply circuit board are properly connected. |
|
|
|
| 1. | Turn off the power and clean the exhaust cooling fan. |
|
|
|
|
| (Remove dust.) |
|
| Exhaust fan problem | 2. | Check that connectors P1 and P20 on the main P.C. board |
| |
|
| are properly connected. |
| ||
|
|
|
|
| |
|
|
| 3. | Check that connectors CN2, CN3 and CN4 on the |
|
|
|
|
| power supply circuit board are properly connected. |
|
|
|
| 1. | Turn off the power. |
|
|
|
| 2. | Check that connector P3 on the sub P.C. board is properly |
|
|
|
|
| connected. |
|
|
|
| 3. | Check that connectors P3 and P4 on the |
|
|
| supply circuit board are properly connected. |
| ||
| 4. Check that connectors P10 and P13 on the sub P.C. board |
| |||
|
| relay error |
| are properly connected. |
|
|
|
|
|
| |
|
|
| 5. | Check that connectors P22 and P23 on the main P.C. |
|
|
|
|
| board are properly connected. |
|
|
|
| * | This error can occur if a |
|
|
|
|
| used with a |
|
| X pitch error | Turn off the power and initialize the parameter settings. |
| ||
| Y pitch error | Turn off the power and initialize the parameter settings. |
| ||
| Use the programming device (the programming software for |
| |||
| the electronic pattern sewer or a programmer) to delete |
| |||
|
|
|
| ||
| Overall cycle program stitch no. error | Clear the cycle program to reset the error automatically. |
| ||
| (Exceeds 3,000 stitches.) |
| |||
|
|
|
|
|
86 |