Installing the 2H22-08R

3.4INSTALLING THE 2H22-08R

The 2H22-08R may be installed on a tabletop, shelf, or in a 19-inch rack. Section 3.4.1 provides the rules and instructions for a tabletop and shelf installations, and Section 3.4.2 provides the rules and instructions for a rackmount installation.

To ensure proper ventilation and prevent overheating, leave a

!minimum clearance space of 5.1 cm (2.0 in) at the left, right,

CAUTION

and rear of the 2H22-08R.

 

3.4.1Tabletop and Shelf Installations

Tabletop and shelf installations must be within reach of the network cabling and meet the requirements listed below:

Locate the 2H22-08R within seven feet of an appropriately grounded power source and an unrestricted surface area as shown in Figure 3-1that meets the power supply requirements listed in Appendix A.

In a shelf installation, the shelf must support 13.6 kg (30 lb) of static weight for each 2H22-08R.

Maintain a temperature of between 5°C (41°F) and 40°C (104°F) at the installation site with fluctuations of less than 10°C (18°F) per hour.

A

C

B

 

PWR

 

 

 

 

 

 

 

2H22-08R

CPU

 

 

 

 

 

 

 

1 2 3 4 5 6

2X

3X

4X

5X

6X

7

8

COM

1X

A = 15 cm (6 in)

D

 

B = 45 cm (22.5 in)

 

C = 53 cm (21 in)

 

D = 213 cm (7 ft)

 

2251-06

Figure 3-1 Tabletop or Shelf Installation

2H22-08R SmartSwitch 2208 User’s Guide

Page 3-3