Chapter 4: Troubleshooting

Table 4-3 FE-100TX LED Indications

LED

Color

Description

 

 

 

 

 

 

 

 

No link or no cable attached. FE-100TX is

10/100

Off

forced or Auto-Negotiates to 10 Mbps

 

operation.

 

 

 

 

Green

FE-100TX is operating at 100 Mbps.

 

 

 

4.3TROUBLESHOOTING CHECKLIST

If the 2H22-08R is not working properly, refer to Table 4-4for a checklist of possible problems, causes, and recommended actions to resolve the problem.

Table 4-4 Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

 

 

 

 

 

 

 

 

Check the proper

 

Loss of Power to the 6C105

connection of the power

All LEDs are OFF.

chassis.

cable and its access to a

 

live outlet.

 

 

 

 

 

 

2H22-08R not properly

Check the installation.

 

installed.

 

 

 

 

 

 

Autobaud enabled.

Press ENTER (RETURN)

 

(may take up to four times).

No Local

 

 

 

Terminal setup is not

Refer to Chapter 5 for

Management

correct.

proper setup procedures.

Password screen.

 

 

Improper console cable

Refer to Appendix A for

 

 

pinouts.

proper console port pinouts.

 

 

 

 

Improper Community

Refer to Chapter 5

 

for Community Names

 

Names Table.

 

Table setup.

Cannot contact the

 

 

 

 

Refer to Chapter 5 for IP

2H22-08R from

2H22-08R does not have an

in-band

address assignment

IP address.

management.

procedure.

 

 

Port is disabled.

Enable port.

 

 

 

 

No link to device.

Check link to device.

 

 

 

Page 4-4

2H22-08R SmartSwitch 2208 User’s Guide

Page 42
Image 42
Cabletron Systems 2208 manual Troubleshooting Checklist, Color Description