Chapter 5: Local Management

6.Use the arrow keys to highlight the SAVE command. Press ENTER. The message “SAVED OK” displays and Local Management saves the changes to memory.

5.11.4Configuring an FE-100FX or FE-100F3 Interface for Port 7 or 8

When an FE-100FX or FE-100F3 is installed in port 7 or 8, it must be manually set to operate in the same technology as the device at the other end of the connected segment. Section 5.11.5 provides instructions for manually setting the port with an FE-100FX or FE-100F3 interface.

5.11.5Setting the FE-100FX and FE-100F3 in Operational Mode

Use this field to set the active technology. This field toggles between 100Base-FXand 100Base-FXFD(full duplex). To set the active technology through Local Management, proceed as follows:

1.Use the arrow keys to highlight the Desired Operational Mode field.

2.Use the SPACE bar to select 100Base-FXor 100Base-FXFD(full duplex).

3.Press ENTER. The port now operates in the chosen mode.

4.Use the arrow keys to highlight the SAVE command. Press ENTER. The message “SAVED OK” displays and Local Management saves the changes to memory.