Table A-2. Transmitter Power

Parameter

Typical Value

Worst

Worst Case

Typical

Case

Budget

Budget

 

 

 

 

 

 

 

 

 

 

 

 

50/125 ∝m

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

fiber

 

 

 

 

 

 

 

 

 

62.5/125 ∝m

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

fiber

 

 

 

 

 

 

 

 

 

100/140 ∝m

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

fiber

 

 

 

 

 

 

 

 

 

Error Rate

Better than 10-10

 

 

 

 

 

 

 

 

NOTE

The transmitter power levels and receive sensitivity levels listed are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given above to those measured on any particular port. If Power Levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed (i.e., -30.5 dBm peak = -33.5 dBm average).