EPIM Specifications

EPIM-F3

The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal Cabletron Systems FOT-F™ Fiber Optic Transceiver and is equipped with ST Connectors. Figure A-3shows the EPIM-F3. Specifications for the EPIM-F3 are listed in Figure A-4and Table A-3.

Figure A-3. EPIM-F3

 

 

 

 

 

 

 

Maximum Sensitivity (-36.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive

 

 

 

 

 

 

Typical Sensitivity (-31.0)

 

 

 

 

Sensitivity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Sensitivity (-30.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Receive Input (-9.72)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Receive Input (-7.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Receive Input (-6.99)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmitter Power*

 

 

 

 

 

 

 

 

 

 

 

Maximum Transmit Power (-12.0)

 

(At 25°C into

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Transmit Power (-15.5)

 

8.3/125m fiber)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Transmit Power (-21.0)

 

dBm

-40

-35

-30

-25

-20

-15

-10

 

 

-5

0

 

Less Power

 

 

 

 

 

 

 

 

 

 

 

 

 

More Power

* Transmit Power

 

Typical Power

 

 

 

 

Minimum Power

 

 

Maximum Power

Coefficient

 

-0.15dBm/°C

 

 

 

 

-0.12 dBm/°C

 

 

-0.18 dBm/°C

(See Note Below)

 

 

 

 

 

 

 

Figure A-4. EPIM-F3 Power and Sensitivity Specifications

NOTE

Transmitter Power decreases as temperatures rise and increases as temperatures fall. Use the Output Power Coefficient to calculate increased or decreased power output for your operating environment. For example, the typical power output at 25°C is -16.4 dBm. For a 4°C temperature increase, multiply the typical coefficient (-0.15 dBm) by four and add the result to typical output power (4 x -0.15 dBm + -16.4 = -17.0).

A-4

Page 42
Image 42
Cabletron Systems 9C300-1 manual EPIM-F3