ELS10-26 MIB

STATUS

mandatory

 

DESCRIPTION

The time, in centiseconds, since

 

the last ECHO-RESPONSE was

 

received (or the last

 

ECHO-RESPONSE was sent, if

 

there have been no responses)

 

when the ping request will time

 

out. This variable cannot be set

 

while the lxpingOperation is on.

::= {lxpingEntry 7}

 

 

lxpingOperation OBJECT-TYPE

 

 

SYNTAX

INTEGER {on (1), off (2) }

ACCESS

read-write

STATUS

mandatory

DESCRIPTION

Setting lxpingOperation to on

 

will begin the ping request. Set-

 

ting lxpingOperation to off will

 

terminate the ping request.

::= {lxpingEntry 8}

 

 

lxpingMin OBJECT-TYPE

 

 

SYNTAX

TimeTicks

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The minimum round trip time

 

for the ping requests and

 

responses, in centiseconds.