ELS10-26 MIB

lxswBases

{lxswFilesetEntry 7}

Octet String Read-Only

 

An array (4 octets per file), containing the software’s base loading address of each of the files. Each address is encoded as a series of 4 bytes, which should be converted into a 32-bit integer.

lxswFlashBank

{lxswFilesetEntry 8}

Integer Read-Only

 

The bank number where the software file set resides. The possible values are:

first-bank (1)

second-bank (2)

6.1.3 Administration Group

lxadminFatalErr

{lxadmin 1}

Octet String Read-Only

 

This is a 32-byte array which contains information about the cause of the previous system reset. This will describe the circumstances which forced the system software to perform a reboot. The values in the first byte have the following meanings:

(0) - Power failure

(1) - Watchdog Timeout

(2) - NMS Requested Shutdown; next three bytes are not applicable; next four bytes contain the NMS’s IP address; remaining 24 bytes are not applicable)

(3-255) - Fatal Error

6-6

Page 118
Image 118
Cabletron Systems ELS10-26 manual Administration Group