5.3 UNIT RUNS BUT HAS INSUFFICIENT COOLING |
| ||
|
|
| |
| Abnormal pressures | 5.7 | |
|
|
| |
| Abnormal temperatures | 5.15 | |
|
|
| |
| Abnormal currents | 5.16 | |
|
|
| |
| Controller malfunction | 5.9 | |
|
|
| |
| Evaporator fan or motor defective | 6.17 | |
|
|
| |
| Shortage of refrigerant | 6.7.1 | |
Refrigeration System |
|
| |
Suction modulation valve lost track of step count | Power cycle | ||
|
|
| |
| Suction modulation valve malfunction | 6.20 | |
|
|
| |
| Compressor service valves or liquid line shutoff valve par- | Open valves | |
| tially closed | completely | |
| Economizer solenoid valve or TXV malfunction | 6.14, 6.19 | |
|
|
| |
| Unloader valve stuck open | 6.19 | |
|
|
| |
| Frost on coil | 5.10 | |
|
|
| |
5.4 UNIT WILL NOT HEAT OR HAS INSUFFICIENT HEATING |
| ||
|
|
| |
| Check | ||
|
|
| |
No operation of any kind | Circuit breaker OFF or defective | Check | |
| External power source OFF | Turn ON | |
|
|
| |
| Circuit breaker or fuse defective | Replace | |
|
|
| |
| Control Transformer defective | Replace | |
|
|
| |
No control power | Evaporator fan internal motor protector open | 6.17 | |
| Heat relay defective | Check | |
|
|
| |
| Heater termination thermostat open | 6.15 | |
|
|
| |
| Heater(s) defective | 6.15 | |
|
|
| |
| Heater contactor or coil defective | Replace | |
|
|
| |
| Evaporator fan motor(s) defective or rotating backwards | 6.15/6.17 | |
|
|
| |
Unit will not heat or has insuffi- | Evaporator fan motor contactor defective | Replace | |
cient heat | Controller malfunction | 5.9 | |
|
|
| |
| Defective wiring | Replace | |
|
|
| |
| Loose terminal connections | Tighten | |
|
|
| |
| Low line voltage | 2.3 | |
|
|
| |
5.5 UNIT WILL NOT TERMINATE HEATING |
| ||
|
|
| |
| Controller improperly set | Reset | |
|
|
| |
Unit fails to stop heating | Controller malfunction | 5.9 | |
|
| ||
Heater termination thermostat remains closed along with | 6.15 | ||
| |||
| the heat relay | ||
|
| ||
|
|
| |
5.6 UNIT WILL NOT DEFROST PROPERLY |
| ||
|
|
| |
| Defrost timer malfunction (Cd27) | Table | |
| Loose terminal connections | Tighten/ | |
|
|
| |
Will not initiate defrost | Defective wiring | Replace | |
automatically |
|
| |
Defrost temperature sensor defective or heat termination | Replace | ||
| thermostat open | ||
|
| ||
|
|
| |
| Heater contactor or coil defective | Replace |