3.1.1 Key Pad
The key pad (Figure 3- 2) is mounted on the
CODE | PRE |
SELECT | TRIP |
ALARM | DEFROST |
LIST | INTERVAL |
| |
ENTER | |
RETURN | _C |
SUPPLY | _F |
BATTERY | ALT. |
POWER | MODE |
Figure 3- 2 Key Pad
COOL | HEAT DEFROST IN RANGE ALARM | SUPPLY RETURN | |
| SETPOINT/Code | AIR TEMPERATURE/Data |
Figure 3- 3 Display Module 3.1.2 Display Module
The display module (Figure 3- 3) consists of two backlighted five digit LCD displays and seven indicator lights. The indicator lights include:
1.Cool - White LED: Energized when the refrigerant compressor is energized.
2.Heat - Orange LED: Energized to indicate heater op- eration in the heat or defrost mode.
3.Defrost - Orange LED: Energized when the unit is in the defrost mode.
4.
| Table | |
|
|
|
KEY |
| FUNCTION |
Code Select |
| Accesses function codes. |
|
|
|
| Displays the | |
| continues | |
|
| |
Alarm List |
| Displays alarm list and clears the alarm |
|
| queue. |
Defrost |
| Displays selected defrost interval. |
Interval |
| |
|
| |
Enter |
| Confirms a selection or saves a selection |
| to the controller. | |
|
| |
Arrow Up |
| Change or scroll a selection upward Pre- |
| trip advance or test interruption. | |
|
| |
Arrow |
| Change or scroll a selection downward. |
Down |
| |
Return/ |
| Displays |
Supply |
| ture (momentary display). |
|
| Displays alternate English/Metric scale |
|
| (momentary display). When set to _F, |
|
| pressure is displayed in psig and vacuum |
|
| in “/hg. “P” appears after the value to in- |
_C/_F |
| dicate psig and “i” appears for inches of |
|
| mercury. |
|
| When set to _C. pressure readings are in |
|
| bars. “b” appears after the value to indi- |
|
| cate bars. |
|
|
|
Battery |
| Initiate battery backup mode to allow set |
| point and function code selection if AC | |
Power |
| |
| power is not connected. | |
|
| |
|
|
|
|
| This key is pressed to switch the functions |
|
| from the temperature software to the Da- |
ALT Mode |
| taCORDER Software. The remaining keys |
| function the same as described above ex- | |
|
| cept the readings or changes are made to |
|
| the DataCORDER programming.. |
|
| NOTE |
The controlling probe in the perishable range will be the SUPPLY air probe and the control- ling probe in the frozen range will be the RETURN air probe.
5.Supply - Yellow LED: Energized when the supply air probe is used for control. When this LED is illumi- nated, the temperature displayed in the AIR TEMPER- ATURE display is the reading at the supply air probe. This LED will flash if dehumidification or humidifi- cation is enabled.
6.Return - Yellow LED: Energized when the return air probe is used for control. When this LED is illumi- nated, the temperature displayed in the AIR TEM- PERATURE display is the reading at the return air pro- be. This LED will flash if dehumidification or humidification is enabled.
7.Alarm - Red LED: Energized when there is an active or an inactive shutdown alarm in the alarm queue