Introduction

MediaVault 4440 User Manual

About Your MV 4440

Congratulations on purchasing the MV 4440 from Ciprico Inc., a leader in performance, quality, and storage for video editing and storage.

The MV 4440 contains 4 modules, called "vPODs". Each vPOD is a 10-drive array. The MV 4440 storage system utilizes the latest RAID 6 drive protection and 4Gb Fibre Channel interface technology. RAID 6 provides for two-drive-down redundancy. In an unlikely event that two drives are down in a vPOD the data is still protected and available.

TABLE 2-1.Features of the MV 4440.

Feature

Number or Value

 

 

Fibre Channels

Two 4Gb Fibre Channels, with two ports per channel

 

 

Fibre Channel interface

Compatible with earlier generation optical Fibre Channel

 

 

RAID Controller

One per vPOD

 

 

RAID levels

RAID 0 or RAID 6 modes

 

 

vPOD

The MV 4440 consists of four vPODs. Each vPOD has ten 2.5-

 

inch disk drives and a RAID controller. The system therefore can

 

contain up to 4 vPODs (40 disk drives and four RAID controllers)

Disk drive modules

40 2.5-inch disk drive modules

 

 

Real Time RAID (RTR) capability

RTR reconstructs data "on the fly" should a drive "glitch"

 

 

Data rate (internal)

500 MBytes/sec per RAID controller

 

 

Date rate for four striped vPODs

1000-1200 MBytes/sec

 

 

Burst rate (maximum) per channel

380 MBytes/sec per RAID controller

 

 

Sustained data rate per channel

300 MBtyes/sec per RAID controller

 

 

Mode Selection

Easy user selection of functionality via Mode Selection and

 

Mode Set switches. No complicated software setup or

 

maintenance

 

 

Fans

Multiple cooling fans

 

 

Serial port

One serial port on each vPOD for maintenance and support

 

 

Alarm

Audible alarm and LED indicators

 

 

Power Supply

One removable power supply module (containing two power

 

supplies)

2-2

MV 4440_Ciprico Inc.

Page 20