Mode Set Button
This is a
•Change the mode (RAID level).
•Mute the audible alarm.
•Start a rebuild process, if the MV 4440 is in RAID 6 mode.
TABLE 5-6. Mode Set Button Functions
Indicator | Description |
|
|
Mode Set Button | Used during the mode change procedure (see page |
(for Mode changes) | Press and hold this switch and apply power to the MV 4440. A double beep confirms |
| |
| the mode change. |
| Release the switch after the double beep. The new Mode selection is now set. |
|
|
Mode Set Button | In RAID 6 mode, and when a drive is marked as “down,” this switch is used to start |
(for drive rebuilds) | the drive rebuild process. |
| After the alarm has been muted, press and hold the Mode Set button until you hear |
| two beeps. The rebuild process has now started. |
| See the “Audible Alarm” section and the “vPOD |
| Chapter 8, Maintenance) for additional information. |
|
|
NOTE: If a drive has been marked as failed, the vPOD will not double- beep if a drive is marked as down, and the Mode Set button is held down while
However, to clear this mode anyway, change the mode to Mode 0, then back to the previous mode.