Cisco Systems ATA 186 SigTimer, 5-26, Description, Value Type, Default, Bit Number, Definition

Models: ATA 188 ATA 186

1 208
Download 208 pages 28.48 Kb
Page 100
Image 100
SigTimer

Chapter 5 Parameters and Defaults

Operational Parameters

SigTimer

Description

This parameter controls various timeouts. Table 5-3contains bit definitions of this parameter.

Value Type

Bitmap

Default 0x00000064

 

Voice Configuration Menu Access Code

 

318

Table 5-3 SigTimer Parameter Bit Definitions

 

 

Bit Number

Definition

 

 

0-7

Call waiting period—The period between each burst of call-waiting tone.

 

Range: 0 to 255 in 0.1 seconds

 

Default: 100 (0x64=100 seconds)

 

 

8-15

PING period—Period in idle state before the Cisco ATA sends a NTFY command with observed event "O:

 

X-NET/ping" to the call agent. Idle state is defined as the state when the Cisco ATA is not sending or

 

receiving any MGCP request or response; the Cisco ATA does not process any response to the PING from

 

the Call Agent.

 

Range: 0 to 255 seconds

 

Default: 0 (disables this feature)

 

 

16-25

Reserved—Should be set to 0.

 

 

26-27

Minimum hook flash time—The minimum on-hook time required for a hook flash event.

 

Range: 0 to 3

 

Default: 0 (60 ms)

 

Other possible values: 1=100 ms, 2=200 ms, 3=300 ms.

 

 

28-31

Maximum hook flash time—The maximum on-hook time allowed for a hook flash event.

 

Range: 0 to 15

 

Default: 0 (1000 ms)

 

Other possible values: 1=100 ms, 2=200 ms, 3=300 ms, 4=400 ms, 5=500 ms, 6=600 ms, 7=700 ms, 8=800

 

ms, 9=900 ms, 10=1000 ms, 11=1100 ms, 12=1200 ms, 13=1300 ms, 14=1400 ms, 15=1500 ms.

 

 

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide for MGCP (version 3.0)

5-26

OL-4803-01

 

 

Page 100
Image 100
Cisco Systems ATA 186 SigTimer, 5-26, Description, Value Type, Default, Voice Configuration Menu Access Code, Bit Number