Cisco Systems ATA 186 Recommended Values, Specific Tone Parameter Information, DialTone, 5-36

Models: ATA 188 ATA 186

1 208
Download 208 pages 28.48 Kb
Page 110
Image 110
Recommended Values

Chapter 5 Parameters and Defaults

Tone Configuration Parameters

Table 5-6 Reorder Tone Parameter Example 2 Explanation (continued)

Component

Setting

Explanation

 

 

 

NumOfRepeats

5

First on-off pair of the cadence plays six times

 

 

(plays once and then repeats five times), then

 

 

the second on-off pair plays

 

 

 

TotalToneTime

0

Tone plays continuously (set of two on-off

 

 

pairs of the cadence repeat continuously) until

 

 

another call event stops the tone

 

 

 

Recommended Values

The following settings are recommended for the US:

DialTone = "2,31538,30831,1380,1740,1,0,0,1000" (approximately -17 dBm)

BusyTone = "2,30467,28959,1191,1513,0,4000,4000,0" (approximately -21 dBm)

ReorderTone = "2,30467,28959,1191,1513,0,2000,2000,0" (approximately -21 dBm)

RingBackTone = "2,30831,30467,1943,2111,0,16000,32000,0" (approximately -16 dBm)

CallWaitTone = "1,30831,0,5493,0,0,2400,2400,4800" (approximately -10 dBm)

AlertTone = “1,30467,0,5970,0,0,480,480,1920”

Note For detailed recommendations of tone-parameter values by country, see Appendix D, “Recommended Cisco ATA Tone Parameter Values by Country.”

Specific Tone Parameter Information

Brief descriptions, and lists of default values and the voice configuration menu code for each Cisco ATA tone parameter, appear in the following sections:

DialTone, page 5-36

BusyTone, page 5-37

ReorderTone, page 5-37

RingbackTone, page 5-38

CallWaitTone, page 5-38

AlertTone, page 5-39

DialTone

Description

The Cisco ATA plays the dial tone when it is ready to accept the first digit of a remote address to make an outgoing call.

Default values (using the Basic format)

NumOfFreqs—2

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide for MGCP (version 3.0)

5-36