Cisco Systems ATA 186 Possible Causes for Failure, Possible Cause for Failure, 6-18, Analysis

Models: ATA 188 ATA 186

1 208
Download 208 pages 28.48 Kb
Page 136
Image 136
Possible Causes for Failure

Chapter 6 Configuring and Debugging Fax Services

Debugging the Cisco ATA 186/188 Fax Services

Example 6-6 Cisco ATA Configuration Failure

----------

FAX Summary 1 ----------

[

37]<2.53=>3.200>

Codec G723

[

39]<3.200=>2.53>

Codec G723

Analysis

<2.53> is the originating gateway and <3.200> is the terminating Cisco ATA.

The Cisco ATA and the <2.53> gateway use G.723 codec.

Possible Causes for Failure

The Cisco ATA is not configured with fax mode or fax pass-through mode.

If the Cisco ATA is the gateway for a fax sender, the remote gateway is not configured with fax pass-through mode.

Example 6-7 Fax Mode Failure

----------

FAX Summary 1 ----------

[

37]<2.53=>3.200>

Codec G711

[

39]<3.200=>2.53>

Codec G711

[ 1820]<2.53=>3.200>

NSE PT

96, Cisco Fax Relay

[ 1966]<2.53=>3.200>

NSE PT

96, Cisco Fax Relay

Analysis

<2.53> is the originating gateway and <3.200> is the terminating Cisco ATA.

The Cisco ATA and the <2.53> gateway begin with G.711 codec.

The <2.53> gateway sends Cisco fax relay event packets.

Possible Cause for Failure

Cisco fax relay option is not disabled on the gateway.

Example 6-8 Fax Pass-through Mode Failure

---------- FAX Summary 1

----------

[

2]<2.53=>3.200>

Codec G723

[

4]<3.200=>2.53>

Codec G723

[

106]<3.200=>2.53>

Codec G711u/D

[

107]<3.200=>2.53>

NSE

PT 100, EVT 192: Up-Speed, CED tone Detected

[ 1436]<3.200=>2.53>

NSE

PT 100, EVT 192: Up-Speed, CED tone Detected

Analysis

<2.53> is the originating gateway, and <3.200> is the terminating Cisco ATA.

The Cisco ATA upspeeds to G.711µ-law and sends G.711 upspeed NSE signaling packets.

The <2.53> gateway does not respond to the NSE signaling packets.

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide for MGCP (version 3.0)

6-18

OL-4803-01

 

 

Page 136
Image 136
Cisco Systems ATA 186, ATA 188 manual Possible Causes for Failure, Possible Cause for Failure, 6-18, Analysis