ReorderTone Parameter Example1

Chapter 5 Parameters and Defaults

Tone Configuration Parameters

TotalToneTime is the total length of time that the tone plays. If this value is 0, the tone will play until another call event stops the tone.

This value is in 10 ms units (100 ms = 1 second).

Two examples of Extended Format B, both using the Reorder tone, follow.

ReorderTone Parameter Example1

Assume that you want a reorder tone in which:

The frequencies 900 Hz, 1400 Hz, and 1800 Hz play sequentially.

Each frequency plays once for 0.33 seconds.

There is no silence after the first and the second frequencies.

There is 1 second of silence after the third frequency (before the first frequency starts again)

The volume of each frequency is –19 dBm.

The tone plays until another call event stops the tone.

For this reorder tone, make the following setting. See Table 5-5for a detailed explanation.

ReorderTone:101,3,24917,3405,14876,4671,5126,5178,3,2640,0,2640,0,

2640,8000,0,0

Table 5-5 Reorder Tone Parameter Example 1 Explanation

Component

Setting

Explanation

 

 

 

Sequential

101

Frequencies play sequentially

 

 

 

NumOfFreqs

3

Three frequencies in the tone

 

 

 

TFreq1

24917

First frequency is 900 Hz

 

 

 

TAmpl1

3405

First frequency volume is –19 dBm

 

 

 

TFreq2

14876

Second frequency is 1400 Hz

 

 

 

TAmp2

4671

Second frequency volume is –19 dBm

 

 

 

TFreq3

5126

Third frequency is 1800 Hz

 

 

 

TAmp3

5178

Third frequency volume is –19 dBm

 

 

 

NumOfOnOffPairs

3

Three on-off pairs in the cadence of the tone

 

 

 

OnTime1

2640

Sound in first on-off pair plays for 0.33

 

 

seconds

 

 

 

OffTime

0

No silence after the first sound (the second

 

 

sound plays immediately)

 

 

 

OnTime2

2640

Sound in second on-off pair plays for 0.33

 

 

seconds

 

 

 

OffTime2

0

No silence after the second sound (the third

 

 

sound plays immediately)

 

 

 

OnTime3

2640

Sound in third on-off pair plays for 0.33

 

 

seconds

 

 

 

OffTime3

8000

1 second of silence after the sound in the third

 

 

on-off pair (before the pattern repeats,

 

 

beginning with the first on-off pair)

 

 

 

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide for MGCP (version 3.0)