Trunk Cards 4-41
Network Trunk Module
Figure 4-24 BC-E1 Faceplate
Table4-18 BC-E1 Connections and Status LEDs
Connector/Indicator Function
RX-TX Female DB-15 connector for XMT and RCV E1.
RX BNC connector for receive E1 line.
TX BNC connector for transmit E1 line.
LOS light (red) Indicates loss of signal at the local end.
Red alarm light Indicates loss of local frame alignment. On an NTM, Red indicates loss of packet
alignment.
Yellow alarm light Indicates loss offrame alignment at remote end. Onan NTM, Yellowalarm indicates loss of
packet alignment.
AIS light (green) Indicates the presence of all ones on the line.
MFRA light (red) Indicates loss of multiframe alignment (E1 only).
MFYA light (yellow) Indicates loss of multiframe at remote end (E1 only).
Fail light (red) Indicates an error. Reset the card withresetcd f. If the LED comes on again, call the TAC.
Active: light (green) Indicates the card is in service with active circuits.
BC-E1
Fail (red)
Active (green)
RX
RX/TX
TX
H8317
LOS (red)
Red alarm (red)
Yellow alarm (yellow)
AIS (green)
MFRA (red)
MFYA (yellow)