Cisco Systems OL-7821-04 Removing and Replacing a Power Supply Unit, Power Supply Specifications

Models: SCE 1000 2xGBE OL-7821-04

1 131
Download 131 pages 61.9 Kb
Page 54
Image 54
Power Supply Specifications

Chapter 4 Installation and Maintenance

Removing and Replacing a Power Supply Unit

Power Supply Specifications

The following table lists the AC-input and DC-input power supply specifications for the SCE

1000 platform:

Table 4-7

SCE 1000 Power Supply Specifications

 

 

 

AC-input power

 

200W maximum

 

 

AC-input voltage rating

100 to 240 VAC

 

 

AC-input current rating

Rated for 4.5A when Vin = 100 VAC or 2A when Vin = 200 VAC

 

 

AC-input frequency rating

50 to 60 Hz

 

 

 

AC-input cable

 

18 AWG three-wire cable, with a three-lead IEC-320 receptacle on

 

 

the power supply end, and a country-dependent plug on the power

 

 

source end.

 

 

 

DC-input power

 

200W maximum

 

 

DC-input voltage rating

–48/-60 VDC nominal (–36 to–72 VDC supply tolerance)

 

 

DC-input current rating

7A at –48 VDC

 

 

 

DC-input cable

 

12 AWG or 2.5-mm copper installation wire with hex or loop

 

 

connectors

 

 

DC-input circuit breaker

One Fast 10A for each power supply unit

 

 

 

Note For AC-input power, we recommend powering the SCE 1000 platform from a 120 VAC, 15A receptacle U.S. (240 VAC, 10A international) at the power source.

Removing and Replacing a Power Supply Unit

The procedures for removing and replacing the AC-input or DC-input power supply are explained in the following sections:

Powering Down the Power Supply Unit and Disconnecting Input Power (on page 4-15)

Removing the Power Supply Unit (on page 4-16)

Replacing the Power Supply Unit (on page 4-17)

Reconnecting the Power (on page 4-17)

ESD Warning Do not remove or install modules without using appropriate anti-static guard measures. The SCE 1000 includes an anti-static wrist strap in the accessory kit. Attach the copper tape strap to an unpainted metal surface on the chassis. You may leave the strap connected to the chassis when your have finished.

Cisco SCE 1000 2xGBE Installation and Configuration Guide

4-14

OL-7821-04

 

 

 

 

Page 54
Image 54
Cisco Systems OL-7821-04, SCE 1000 2xGBE manual Removing and Replacing a Power Supply Unit, Power Supply Specifications