Installing the SCE 1000 Platform

Chapter 4 Installation and Maintenance

Installing the SCE 1000 Platform

*Short term is defined as not more than 96 consecutive hours, not more than 15 days in one year. 360 hours total in any given year, but no more than 15 occurrences in a one-year period.

Table 4-3

SCE 1000 Approvals Specifications

 

 

 

Approval

 

Specification

 

 

 

EMC

 

• CE Mark

 

 

• EMISSIONS: FCC Part 15 CFR 47 Class A, EN 55022 Class A, CISPR22

 

 

Class A, VCCI Class A, AS/NZS CISPR22 Class A

 

 

• Immunity - EN 50082-1 EN 55024, CISPR24 (ESD, RFI, EFT, etc.)

 

 

(Commercial)

 

 

 

Safety

 

UL/CSA 60950, IEC60950, EN60950, AS/NZS, 60950, NOM-

 

 

019,IEC/EN60825-1, -2, 21CFR1040, 73/23/ECC

 

 

 

For more complete information regarding safety and regulatory compliance, refer to the Regulatory Compliance and Safety Information for the Cisco Service Control Engine document.

Warning The DC-powered SCE 1000 should be installed in a Restricted Access Location only.

Installing the SCE 1000 Platform

The SCE 1000 operates as either a tabletop or a rack-mounted unit. A rack-mounting kit is included with the SCE 1000 when it is shipped from the factory. The kit provides the hardware needed (see SCE 1000 Component List (on page 2-5)) to mount the SCE 1000 in either of two types of standard 19-inch equipment rack:

19-inch rack with only two posts in the front — Use the supporting brackets included in the kit

19-inch rack with four posts, two in the front and two in the back — Use the crossrail supports included in the kit

If you are not rack-mounting your SCE 1000, place it on a sturdy tabletop or workbench. A rubber feet kit is included for tabletop installations.

This section provides instructions for the physical installation of the SCE 1000 platform, including how to install the SCE 1000 in a rack, how to install the SCE 1000 on a tabletop or workbench, and how to properly ground the SCE 1000 platform. The section contains the following topics:

Installation Precautions (on page 4-5)

Installing the SCE 1000 on a Workbench or Tabletop (on page 4-5)

Rack-Mounting a SCE 1000 Platform ("Rack-Mounting a SCE 1000 Platform" on page 4-6)

Attaching a Chassis Ground Connection (on page 4-10)

Cisco SCE 1000 2xGBE Installation and Configuration Guide