Figure 4-15: Connecting the DC Power

Chapter 4 Installation and Maintenance

Removing and Replacing a Power Supply Unit

Warning Wiring should be done by a professional in accordance with state and local electrical codes.

To reconnect the DC-input power to the SCE 1000 platform, complete the following steps:

Step 1 Ensure that the DC power line input leads are disconnected from the power source.

Step 2 Using the number 2 Phillips screwdriver, remove the protective plate from the terminal block.

Step 3 Insert one receptacle screw into the hex or loop connector on one power line input, insert the screw with the connector into the corresponding lead receptacle and tighten the receptacle screw using the number 2 Phillips . Repeat for the remaining power line input lead.

Figure 4-15: Connecting the DC Power

Note The color coding of the DC-input power supply leads depends on the color coding of the DC power source at your site. Make certain the lead color coding you choose for the DC-input power supply matches lead color coding used at the DC power source.

Note Use 12 AWG (2.5 mm) copper wire only with hex or loop connectors. Ring terminals must be UL approved and suitable for 12 AWG wire.

Step 4 Using the number 2 Phillips screwdriver, securely fasten the protective plate to the terminal block. Step 5 Connect the DC power line input leads to the DC power source through a fast 10A circuit breaker. Step 6 Turn the on/off switch to the on (⏐) position.