Connection Log Messages

CNWR-811P User Guide

Refresh

Contact this device and update the Log data.

Connection Log Messages

Message

Description

Connect on

Connection attempt has been triggered by the "Connect on De-

Demand

mand" setting.

 

 

Manual connection

Connection attempt started by the "Connect" button.

 

 

Reset physical

Preparing line for connection attempt.

connection

 

 

 

Connecting to remote

Attempting to connect to the the ISP's server.

server

 

 

 

Remote Server

ISP's Server has responded to connection attempt.

located

 

 

 

Start PPP

Attempting to login to ISP's Server and establish a PPP connection.

 

 

PPP up successfully

Able to login to ISP's Server and establish a PPP connection.

 

 

Idle time-out reached

The connection has been idle for the time period specified in the

 

"Idle Time-out" field. The connection will now be terminated.

 

 

Disconnecting

The current connection is being terminated, due to either the "Idle

 

Time-out" above, or "Disconnect" button being clicked.

 

 

Error: Remote Server

ISP's Server did not respond. This could be a Server problem, or a

not found

problem with the link to the Server.

 

 

Error: PPP Connec-

Unable to establish a PPP connection with the ISP's Server. This

tion failed

could be a login problem (name or password) or a Server problem.

 

 

Error: Connection to

The existing connection has been lost. This could be caused by a

Server lost

power failure, link failure, or Server failure.

 

 

Error: Invalid or

The data received from the ISP's Server could not be processed.

unknown packet type

This could be caused by data corruption (from a bad link), or the

 

Server using a protocol which is not supported by this device.

 

 

22