| Using |
|
|
|
|
I N S T A L L |
|
|
|
Options | Values | Description | |
|
|
|
|
<BUFFER> |
|
| Assign buffer memory as the input buffer. |
| 2 | KBYTE | 2K bytes |
| 8 | KBYTE | 8K bytes |
| 16 KBYTE | 16K bytes | |
| 32 KBYTE | 32K bytes | |
| 64 KBYTE | 64K bytes | |
|
|
| Note: |
|
|
| The larger the input buffer selected, the smaller the |
|
|
| download buffer reduced. Even with 64K bytes of |
|
|
| input buffer, a minimal download buffer is |
|
|
| provided. If you need a larger capacity for |
|
|
| downloading fonts, reduce the input buffer. |
|
|
|
|
<I/F TYPE> |
|
| Select the type of interface to the computer. |
(Interface Type) | PARALLEL | Centronics parallel interface | |
| SERIAL | ||
| AUTO | Both interfaces are ready for communication. The | |
|
|
| printer communicates with the interface from which it |
|
|
| first receives data. The interface is active until the |
|
|
| input buffer becomes empty. |
|
|
|
|
<AUTO SW> |
|
| Specify the timing of regarding the selected protocol |
(Auto Switch) |
|
| or interface as being inactive when AUTO is specified |
|
|
| in the <PROTOCOL>or <I/F TYPE>option. |
| 2 | SEC | 2 seconds elapsed after data stops from the computer. |
| 4 | SEC | 4 seconds elapsed after data stops from the computer. |
| 6 | SEC | 6 seconds elapsed after data stops from the computer. |
| 8 | SEC | 8 seconds elapsed after data stops from the computer. |
10 | SEC | 10secondselapsedafterdatastopsfromthecomputer. | |
12 | SEC | 12secondselapsedafterdatastopsfromthecomputer. | |
14 | SEC | 14secondselapsedafterdatastopsfromthecomputer. | |
16 | SEC | 16 | seconds elapsed after data stops from the |
|
| computer. | |
18 | SEC | 18 | seconds elapsed after data stops from the |
|
| computer. | |
20 | SEC | 20 | seconds elapsed after data stops from the |
|
| computer. | |
|
|
|
|