Checking the iDR-8 Operating Code Version
A&H iDR | V3.00 |
< | scroll |
|
|
< | > |
| |
|
| ||
ESC |
| ENTER | MENU |
With the face plate removed, press and hold the ESC key to view the current version of operating code running in the unit.
Check that this code is the same version as the iDR System Manager software you have installed on your PC. View this by clicking on the software Help menu About item. If it is an older version then carry out the code update procedure described below. If you have several units connected over a network make sure you check each for the correct version number.
We recommend that you check the Allen & Heath web site for the latest version of software. Download and install this if it is different to that already on your PC.
Updating the iDR-8 Operating Code
IMPORTANT: Make sure all iDR units to be controlled by the PC are running the same version software as installed on the PC.
HyperTerminal settings If you prefer to use an alternative terminal or communications program, or you wish to configure the HyperTerminal connection manually, the required port settings are:
Baud Rate | 115200 |
Data bits | 8 |
Parity | none |
Stop Bits | 1 |
Flow Control | None |
Protocol | 1K Xmodem |
DR Boot | V1.00 |
Update |
|
CODE UPDATE | FRONT/REAR |
active
RS232
For connection to PC com port
Boot code is the
The operating code is held in
The front panel RS232 port is provided for updating the unit operating code from a binary file on the PC. This is done using the Windows™ HyperTerminal application which sends the file to the iDR via the PC RS232 serial port. The file is provided with the iDR System Manager software.
Make sure your PC has the Windows™ HyperTerminal application installed and an available COM1 or COM2 port. Use a standard male to female RS232 lead such as the one supplied with the unit. Do not use a null modem cable.
Refer to any Release Notes which may apply. We recommend that you archive the current configuration before you start the update if the
1Start HyperTerminal From the Start / Programs / Allen & Heath / iDR System Manager menu select the Update iDR Unit Software (COMn) item. Select the COM1 or COM2 version as appropriate for your PC. The HyperTerminal window is opened.
2Select the file to transfer From the Transfer menu select the Send File item. Click on the Browse button. The file named ‘iDR Unit Software V3_nn.bin’ is displayed. Make sure the version number is the same as the one you want to load. Open the file. The Send File window is opened ready to send the file via the COM port. Do not do this until you have prepared the
3Prepare the
4Start the file transfer Click on the HyperTerminal Send button. The transfer starts and a window displays information and a progress bar. The LCD displays ‘Updating…’ progress and then ‘Update Complete’. The process can take a few minutes.
5Restore normal operation Exit HyperTerminal. Deselect the CODE UPDATE switch. The unit reboots automatically. Deselect the FRONT/REAR switch if you want the rear RS232 port to become active. Press ESC to confirm that the correct version of operating code has been loaded.
| 17 |