Rear Panel Overview
Use | MIDI OUT | THRU | MIDI IN |
|
|
|
|
|
| MIC/LINE INPUTS |
|
|
|
|
RS232 (MODEM) | NETWORK |
|
|
| SYSNET PORT |
|
|
|
|
|
|
| ||
|
|
| IN 8 | IN 7 | IN 6 | IN 5 | IN 4 | IN 3 | IN 2 | IN 1 | ||||
MDI/X |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
active | active |
|
| active active |
|
|
|
|
|
|
|
|
| |
TX | LINK | AUDIO OUT |
|
|
|
|
|
|
|
| ||||
Refer to user guide for port selection details |
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| LINE OUTPUTS |
|
|
|
|
100 - 240V~ |
|
|
|
|
|
| OUT 8 | OUT 7 | OUT 6 | OUT 5 | OUT 4 | OUT 3 | OUT 2 | OUT 1 |
| CAUTION 20V DC |
|
|
| ||||||||||
|
| DIGITAL EXPANDER |
|
|
|
|
|
|
|
| ||||
|
| TO AVOID DAMAGE ONLY CONNECT |
|
|
|
|
|
|
|
|
| |||
| FUSE: T1.6AL | COMPATIBLE REMOTE CONTROL | R | MONITOR IN L | R MONITOR OUT L |
|
|
|
|
|
|
|
| |
| EQUIPMENT TO THE |
|
|
|
|
|
|
|
| |||||
WARNING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
THIS APPARATUS MUST BE EARTHED. |
| SERIAL NUMBER |
|
|
|
|
|
|
|
|
|
|
|
|
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. |
| Made in the UK by ALLEN&HEATH LIMITED | Complies with UL6500, |
|
|
|
|
|
|
|
| |||
100 - 240V~ |
| next |
|
| previous |
| IN 16 | IN 15 | IN 14 | IN 13 | IN 12 | IN 11 | IN 10 | IN 9 |
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| OUT | IN | AUDIO OUT |
|
|
|
|
|
|
|
|
| |
| FUSE: T500mAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
WARNING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
THIS APPARATUS MUST BE EARTHED. |
| SERIAL NUMBER |
| DIGITAL EXPANDER |
|
|
|
|
|
|
|
|
| |
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES. |
|
|
|
|
|
|
|
| MIC/LINE INPUTS |
|
|
|
| |
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING. |
| Made in the UK by ALLEN&HEATH LIMITED | Complies with UL6500, |
|
|
|
|
|
|
| ||||
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. |
|
|
|
|
|
|
|
|
| |||||
100 - 240V~ |
| next |
|
| previous |
| OUT 16 | OUT 15 | OUT 14 | OUT 13 | OUT 12 | OUT 11 | OUT 10 | OUT 9 |
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| OUT | IN | AUDIO IN |
|
|
|
|
|
|
|
|
| |
| FUSE: T500mAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
WARNING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
THIS APPARATUS MUST BE EARTHED. |
| SERIAL NUMBER |
| DIGITAL EXPANDER |
|
|
|
|
|
|
|
|
| |
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES. |
|
|
|
|
|
|
|
| LINE OUTPUTS |
|
|
|
| |
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING. |
|
|
|
|
|
|
|
|
|
|
|
| ||
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. |
| Made in the UK by ALLEN&HEATH LIMITED | Complies with UL6500, |
|
|
|
|
|
|
|
|
100 - 240V~
47-63Hz ~ 15W MAX
FUSE: T500mAL
WARNING
THIS APPARATUS MUST BE EARTHED.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING. CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
|
|
|
| +10V DC max total 500mA | V | SWITCH INPUTS | G 24 23 22 21 20 19 18 17 | G | G 16 15 14 13 12 11 10 9 | G | G 8 7 6 5 4 3 2 1 | G | ||
|
|
|
| +10V |
| +10V |
|
|
|
|
|
| ||
|
|
|
| open collector | + | opto |
| 2K2 |
|
|
|
|
|
|
|
|
|
| +24V DC, 200mA max | - | switch | opto |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |||
next |
| previous | LOGIC OUTPUTS | G |
| G |
|
|
|
|
|
|
| |
OUT |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| V +16 - +15 - +14 - +13 - | G |
| V +12 - +11 - +10 - + 9 - | G | V + 8 - + 7 - + 6 - + 5 - | G | V + 4 - + 3 - + 2 - + 1 - G | |||||
|
|
|
|
| ||||||||||
| Made in the UK by ALLEN&HEATH LIMITED | Complies with UL6500, |
|
|
|
|
|
|
|
|
1Mains input Use the IEC lead with moulded mains plug suitable for your local voltage. The protection fuse rating is marked on the rear panel. The on/off switch is positioned on the rear panel to prevent accidental operation.
2Network port RJ45 socket for connection to an Ethernet network or PC using UTP CAT5 cable. This port is recommended for configuring the system with iDR software. The MDI/X switch selects network or direct to PC operation. The link LED lights when communication is established. The TX LED lights when data is communicated.
Note: The RS232, MIDI, SysNet and
3 RS232 (MODEM) port This is used for connection to a modem so that the unit can be interrogated by a remote PC over a standard telephone line. It can also be used for system configuration using iDR System Manager software but the faster network port is recommended. Pressing the front panel switch selects either the front or rear RS232 port.
4MIDI port Standard
5SysNet port An RS232 serial port for communication with third party remote controllers running the Allen & Heath SysNet protocol.
6
7
8 Audio expander ports RJ45 sockets for communicating 8 channel digital audio between the
9Mic/Line inputs Balanced XLR inputs for microphone and line level sources. Adding the
10Audio outputs Balanced XLR line level outputs with maximum +18dBu level. Adding the
11Monitor inputs and outputs Balanced TRS jacks for L and R monitor inputs and outputs. These provide a line level version of the front panel stereo headphones output and can daisy chain through multiple iDR units.
12Switch closure inputs These are provided on the
13Open collector logic outputs These are provided on the
14Earth terminals These are provided to earth (ground) the switch and logic output cable shields.
| 9 |