Adding the iDR-in and iDR-out Audio Expanders

Adding the iDR-in and iDR-out Audio Expanders

lock link power

iDR-in

AUDIO INPUT EXPANDER

lock link power

iDR-out

AUDIO OUTPUT EXPANDER

100 - 240V~

next

 

 

previous

IN 16

IN 15

IN 14

IN 13

IN 12

IN 11

IN 10

IN 9

47-63Hz ~ 25W MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

DR-LINK

IN

AUDIO OUT

 

 

 

 

 

 

 

 

FUSE: T500mAL

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

 

 

 

 

 

 

 

 

 

THIS APPARATUS MUST BE EARTHED.

SERIAL NUMBER

 

DIGITAL EXPANDER

 

 

 

 

 

 

 

 

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

 

 

 

 

 

 

 

MIC/LINE INPUTS

 

 

 

 

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

 

 

 

 

 

 

 

 

 

 

 

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

 

Made in the UK by ALLEN&HEATH LIMITED

Complies with UL6500, CSA-E65, EN60065

 

 

 

 

 

 

 

100 - 240V~

next

 

 

previous

OUT 16

OUT 15

OUT 14

OUT 13

OUT 12

OUT 11

OUT 10

OUT 9

47-63Hz ~ 25W MAX

 

 

 

OUT

DR-LINK

IN

AUDIO IN

 

 

 

 

 

 

 

 

FUSE: T500mAL

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

 

 

 

 

 

 

 

 

 

THIS APPARATUS MUST BE EARTHED.

SERIAL NUMBER

 

DIGITAL EXPANDER

 

 

 

 

 

 

 

 

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

 

 

 

 

 

 

 

LINE OUTPUTS

 

 

 

 

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

 

 

 

 

 

 

 

 

 

 

 

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

 

Made in the UK by ALLEN&HEATH LIMITED

Complies with UL6500, CSA-E65, EN60065

 

 

 

 

 

 

 

iDR-inand iDR-outare add-on audio expander units for the iDR-8audio mix processor. They provide additional analogue audio inputs and outputs to add to those on the main unit. The iDR-inhas 8 mic/line inputs, the iDR-outhas 8 line outputs. Only one of each may be added to the iDR system bringing it up to a maximum 16x16 audio matrix. These units do not have any processing built in. They simply convert the analogue audio to an 8 channel wide digital bus which feeds the main unit via a CAT5 STP cable. The processing is available on the main unit which features the full 16x16 matrix. Both units have 8 front panel LEDs in addition to the 3 status indicators. These are 3-colour soft LEDs which can be assigned as audio meters, mute indicators or static patch related indicators. They are programmed in the usual way using the iDR System Manager software. The iDR-infeatures the same input preamps as the main unit, complete with switchable 48V phantom power, 20dB pad, gain control and pre-converter soft limiter. Control of the expanders is via the DR-Link port using a CAT5 STP cable. This means that two CAT5 cables are required to interconnect an expander to the main unit. Maximum distance between the units is 250 metres. Local mains power is required.

100 - 240V~

47-63Hz ~ 25W MAX

FUSE: T500mAL

Check the connections The iDR-inAUDIO OUTWARNING lock link power

THIS APPARATUS MUST BE EARTHED.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING. CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

next

previous

OUT DR-LINK IN

AUDIO OUT

DIGITAL EXPANDER *8 Diagnostics

Audio Exp:In/Out Make sure you have read the Important Safety Instructions printed earlier. Also check that your local mains supply is compatible with that printed on the rear panel of the unit. Ensure that the correct mains lead with moulded plug and IEC connector has been supplied. For your own safety and optimum performance make sure the system is correctly grounded.

Turning the expander on or off Turn the unit on To avoid any unexpected audible clicks or thumps always turn connected power amplifiers down or off before switching the iDR or any other signal equipment on or off.

Check the connections The iDR-inAUDIO OUT

connects to the iDR-8AUDIO IN. The iDR-outAUDIO IN connects to the iDR-8AUDIO OUT. Ensure that the expander DR-Link IN connects to DR-Link on the iDR-8it is associated with. If both expanders connect to the same iDR-8then daisy chain from DR-Link OUT on one to DR-Link IN on the other.

lock link power

*8 Diagnostics

Audio Exp:In/Out

Turning the expander on or off Turn the unit on

by pressing the rear panel power ON/OFF switch. The power LED lights up. The link LED lights if the DR-Link connection is established with the iDR-8. Then the lock LED lights once audio communication is established with the iDR-8. The iDR System Manager detects the presence of the expander.

Checking for expanders You can use the front

panel iDR-8Setup menus to check if any expanders are connected and working. This is useful when the expanders are located far away from the main unit. With the face plate removed access menu *8 Diagnostics and scroll to Audio Exp.

30