Press <NO> or the down arrow key to leave the relay setting and display the next prompt.

The possible settings for relay output are as follows:

 

Setting

 

 

Result

 

 

 

 

 

 

0-DISABLED

 

The relay remains open at all times and any

 

SWITCH OUTPUT=n

 

 

external devices are disabled.

 

0-DISABLED?

 

 

 

 

N = current setting

 

 

 

 

 

 

 

 

1-CLOCK = 0

 

In count down mode, the relay closes when the

 

SWITCH OUTPUT=n

 

 

main clock reaches zero and remains closed until a

 

1-CLOCK =0?

 

 

nonzero value is entered.

 

 

 

 

 

N = current setting

 

In count up mode, the relay closes when the main

 

 

 

 

 

 

 

 

clock reaches the proper period, break, or overtime

 

 

 

 

length and opens when any other value is entered.

 

 

 

 

 

 

2-CLOCK STOP

 

The relay closes when the main clock is stopped

 

SWITCH OUTPUT=n

 

 

and opens when the main clock is running. External

 

2-CLOCK STOP?

 

 

devices are disabled when the main clock is

 

 

 

running.

 

N = current setting

 

 

 

 

 

 

 

 

 

3-MAIN HORN

 

The relay closes when the main horn sounds. This

 

SWITCH OUTPUT=n

 

 

could be when Auto Horn is enabled and the main

 

3-MAIN HORN?

 

 

clock reaches zero or when <HORN> is pressed.

 

 

 

 

 

N = current setting

 

 

 

 

 

 

 

Default Settings

Write the settings for this installation in the space (Custom) provided.

 

 

Setting

Default

 

Custom 1

Custom 2

Custom 3

 

 

 

 

 

 

 

 

 

 

 

 

Switch Output

1-Clock =0

 

 

 

 

 

 

Auto/Manual Timing

Auto

 

 

 

 

 

 

Round Length

3:00

 

 

 

 

 

 

 

(accessed by key)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rest Length (accessed

1:00

 

 

 

 

 

 

 

by key)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tae Kwon Do Operations

 

 

255

Page 272
Image 272
Daktronics All Sport 5000 manual Setting Result, Tae Kwon Do Operations 255