POWERSCAN® D8330/M8300

5.5.2Enter Sleep Timeout

For readers that have the Sleep state enabled, this timeout determines when the reader will enter this state.

5.6READING PARAMETERS5.6.1Trigger Signal

This mode determines how the reading phase is controlled when the hardware trigger operating mode is selected:

trigger active level: the reader goes ON when the trigger is pressed and goes OFF when it is released

trigger active pulse: the reader goes ON at the first trigger press and goes OFF only at a second press

5.6.2Trigger Click

When enabled, it activates a "click" sound upon each trigger pressure.

5.6.3Trigger-Off Timeout

When this timeout is selected, the reader turns OFF automatically after the desired period of time.

5.6.4Reads per Cycle

In general, a reading cycle corresponds to the ON + OFF times of a device.

The resulting effects of this parameter on code reading depend on other related configuration conditions. Here are the definitions of ON and OFF times.

For readers using the software trigger parameter (FLASH MODE), a reading cycle corresponds to the flash on + flash off times. Code reading takes place during the flash on time.

For readers using the hardware trigger parameter, a reading cycle corresponds to a trigger press (ON) + one of the following OFF events:

trigger release (for trigger active level)

a second trigger press (for trigger active pulse)

trigger-off timeout (see par. 5.6.3).