POWERSCAN® D8330/M8300

POWERSCAN® D8330/M8300 READER DATA ENTRY

Beeper¹

LED

Good Read Spot

Meaning

 

 

 

 

one beep²

ON

ON

Correct read of a code in normal mode

 

 

 

 

H L long

 

 

TX buffer full (when FIFO is enabled) or

 

 

 

TX error between PowerScan® M8300

 

 

 

and BC-8000

H long

ON

ON

Successful advanced format

 

 

 

concatenation

 

 

 

 

H H H

 

 

Timeout expired – operation not

 

 

 

completed

H H long

 

 

Error in advanced data formatting

 

 

 

 

 

OFF

OFF

Ready to read a code

 

 

 

 

¹Only the Beeper Intensity command can modify these signals.

²The data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameters section.

For M-series readers, normally this results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether BC-80X0 has received the data. See also par. 5.9.5.

POWERSCAN® M8300 POWER

Beeper

LED

Meaning

 

 

 

10 short H

10 short blinks

Low Battery

 

 

 

H M L

 

Power off

 

 

 

H = high tone

M = medium tone

L = low tone

POWERSCAN® M8300 BIND, JOIN, COPY COMMANDS

 

Beeper¹

LED

Meaning

 

 

 

 

 

 

Blinking

Command accepted; reader ready to be inserted

 

 

 

into the cradle

 

 

 

 

 

L

 

Success

 

 

 

H L long tones

 

Failure

 

 

 

 

180