POWERSCAN® D8330/M8300
5.14.3Copy BC-80X0Procedure:
cUsing the slave reader and its BC-80X0 cradle, read the Restore Default barcode, set the radio address, and then read the RS-232 interface barcode from chapter 4 of this manual or from the Quick Reference Guide.
dConnect the master BC-80X0 and the slave BC-80X0 (cradle to be configured) together through two RS-232 serial interface cables and external power supply. Accessory cables and power supply are available from your Datalogic distributor to provide this connection.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG12
eRead the Configuration Copy barcode below with a reader. Then place it onto the master BC-80X0 cradle.
Copy Configuration
Ì$+ZZ3$-9ÎThe configuration will be copied from the master BC-80X0 to the slave BC-80X0. The reader signals the end of the procedure with a series of beeps.
fRepeat the procedure above to configure other slave cradles.
Note: The master BC-80X0 can be configured for any interface.
168