POWERSCAN® D8330/M8300
5.7.3Interdigit ControlThe interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar.
5.8ADVANCED FORMATTING5.8.1Match ConditionsSelecting an Advanced Formatting and specifying a Match restriction (Code Type, Code Length, Predefined Characters) the code will be transmitted according to the order of the defined formats.
For example, defining 2 formats where:
•Format 1: Match Code type = Code128
•Format 2: Match Code length = 15 and Match with Predefined Characters “DATA”
a Code128 “DATA:12345ABCDE” with code length 15 will be formatted following the Format 1.
To send the same code with the Format 2 it is necessary to invert the format order as follows:
•Format 1: Match Code length = 15 and Match with Predefined Characters “DATA”
•Format 2: Match Code type = Code128
5.9RADIO PARAMETERS (M8300 SERIES ONLY)5.9.1Radio Protocol TimeoutThis parameter sets the valid time to wait before transmission between the M8300 series reader and
This parameter should be set taking into consideration the radio traffic (number of readers in the same area).
If the
It can be set between 2 and 19 seconds.
158