POWERSCAN® D8330/M8300

5.14 CONFIGURATION COPYING COMMANDS5.14.1Copy PowerScanD8330 SeriesProcedure:

cConnect the master (correctly configured reader) and the slave (reader to be configured) together through two RS-232 serial interface cables and external power supply. Accessory cables and power supply are available from your Datalogic distributor to provide this connection.

RS-232 Cables: CAB471 & CAB472

Power Supply: PG5

dUsing the slave reader, read the Restore Default barcode and then the RS-232 interface barcode from chapter 4 of this manual or from the Quick Reference Guide.

eWith the master reader, read the Configuration Copy barcode below.

Copy Configuration

Ì$+ZZ0$-*Î

The configuration will be copied from the master to the slave reader. The slave reader signals the end of the procedure with a series of beeps.

Note: The master reader can be configured for any interface.

166