Enter Configuration

 

Exit and Save Configuration

Ì$+;Î

DATA FORMAT

Ì$-?Î

Example:

The following strings define:

1.First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character.

2.Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.

first character replacement

Code 39

ASCII characters corresponding to

ASCII

characters corresponding

the HEX value for character 0

to the HEX value for character 1

ÌEO1pÎ +ÌVWÎ +

30

+

31

For Code 39 codes containing the string "0123", the contents transmitted will be "1123".

second character

Code 39

ASCII characters corresponding to

ASCII

characters corresponding

replacement

the HEX value for character A

to the HEX value for character B

 

ÌEO2sÎ+

ÌVWÎ +

41

+

42

For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".

78