General Features
Global Prefix/Suffix
ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data). Scan the bar code below labeled “Scan Options”, then one of the following four bar codes corresponding to the posi- tion(s) you wish to specify:
•Data As Is
•<DATA> <SUFFIX>
•<PREFIX> <DATA>
•<PREFIX> <DATA> <SUFFIX>.
Scan the “Enter” bar code to complete the change. To set values for the prefix and/or suffix, See Prefix/Suffix Values on page 27. Scan the bar code “Data Format Can- cel” if you wish to cancel the change.
If a carriage return/enter is required after each scanned bar code, scan the following bar codes in order:
1.“Scan Options”
2.<DATA> <SUFFIX>
3.“Enter”
Scan Options
*Data As Is
<DATA> <SUFFIX>
28 | QuickScan® L |