RS-232

Table 6. Terminal Specific RS-232

 

 

 

 

Wincor-

Wincor-

 

 

 

Standard

 

 

Nixdorf

 

 

Parameter

ICL

Fujitsu

Nixdorf

Olivetti

Omron

(Default)

Mode B/

 

 

 

Mode A

 

 

 

 

 

 

OPOS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmit

No

Yes

Yes

Yes

Yes

Yes

Yes

Code ID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Transmis-

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Data/Suffix

Prefix/Data/Suf-

Data/Suffix

sion Format

fix

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suffix

CR/LF

CR (1013)

CR (1013)

CR (1013)

CR (1013)

ETX (1002)

CR (1013)

(7013)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud Rate

9600

9600

9600

9600

9600

9600

9600

 

 

 

 

 

 

 

 

Parity

None

Even

None

Odd

Odd

Even

None

 

 

 

 

 

 

 

 

Hardware Hand-

None

RTS/CTS

None

RTS/CTS

RTS/CTS

None

None

shaking

Option 3

Option 3

Option 3

 

 

 

 

 

 

 

 

 

 

 

 

Software Hand-

None

None

None

None

None

Ack/Nak

None

shaking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Response

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

Time-out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop Bit

One

One

One

One

One

One

One

Select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

8-Bit

7-Bit

8-Bit

 

 

 

 

 

 

 

 

Beep On

Disable

Disable

Disable

Disable

Disable

Disable

Disable

<BEL>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RTS Line

Low

High

Low

Low

Low = No data

Low

High

State

to send

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prefix

None

None

None

None

None

STX (1003)

None

 

 

 

 

 

 

 

 

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.

 

**If Nixdorf Mode B is scanned without the scanner connected to the proper host, it may appear unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the scanner.

Table 7. Terminal Specific Code ID Characters

 

 

 

Wincor-

Wincor-

 

 

 

ICL

Fujitsu

Nixdorf

Nixdorf

Olivetti

Omron

 

 

 

Mode A

Mode B/OPOS

 

 

 

 

 

 

 

 

 

UPC-A

A

A

A

A

A

A

 

 

 

 

 

 

 

UPC-E

E

E

C

C

C

E

 

 

 

 

 

 

 

EAN-8/JAN-8

FF

FF

B

B

B

FF

 

 

 

 

 

 

 

34

QuickScan® L

Page 40
Image 40
Datalogic Scanning QD 2300 manual Terminal Specific RS-232, Wincor, Parameter, Terminal Specific Code ID Characters