E07FA

TEMP CPU n

Specified microprocessor is out of

Ensure that the system cooling fans are properly installed. If the problem persists,

 

THERM

acceptable temperature range and is

replace the faulty fan(s) (see "System Fans"). If the problem persists, ensure that the

 

 

operating at a reduced speed, or

microprocessor heat sinks are properly installed. If the problem persists, replace the

 

 

frequency.

faulty microprocessor (see "Microprocessors").

E0876

POWER PS n

No power available from the specified

Ensure that the power supplies are properly installed. If the problem persists, replace

 

 

power supply; specified power supply is

the faulty power supply(s) (see "Power Supplies").

 

 

improperly installed or faulty.

 

 

 

 

 

E0880

INSUFFICIENT

Insufficient power is being supplied to the

 

 

PS

system; power supplies are improperly

 

 

 

installed, faulty, or missing.

 

E0CB2

MEM SPARE

Correctable errors threshold was met in a

Ensure that the memory modules are properly installed. If the problem persists,

 

BANK

memory bank: errors were remapped to

replace the faulty memory module(s) (see "Memory Modules").

 

 

the spare bank.

 

E0CF1

MBE DIMM

Memory modules installed in the specified

Ensure that all banks contain memory modules of the same type and size and that

 

Bank n

bank are not the same type and size;

they are properly installed. If the problem persists, replace the faulty memory module

 

 

faulty memory module(s).

(s) (see "Memory Modules").

E0CF1

POST MEM 64K

Parity failure in the first 64 KB of main

Ensure that the memory modules are properly installed. If the problem persists,

 

 

memory.

replace the faulty memory module(s) (see "Memory Modules").

E0CF1

POST NO

Main-memory refresh verification failure.

Ensure that all banks contain memory modules of the same type and size and that

 

MEMORY

 

they are properly installed. If the problem persists, replace the faulty memory module

 

 

 

(s) (see "Memory Modules").

E0CF5

LOG DISABLE

Multiple single-bit errors on a single

Ensure that the memory modules are properly installed. If the problem persists,

 

SBE

memory module.

replace the faulty memory module(s) (see "Memory Modules").

 

 

 

 

E0D76

DRIVE FAIL

Faulty or improperly installed hard drive or

Ensure that the hard drives are properly installed. If the problem persists, replace the

 

 

RAID controller.

faulty hard drive(s) (see "Hard Drives"). If the problem persists, replace the RAID

 

 

 

controller (see "Integrated RAID Controller" and "RAID Controller Card").

 

 

 

 

E0F04

POST CMOS

CMOS write/read failure; faulty system

Replace the system board (see "System Board").

 

 

board.

 

E0F04

POST CPU

Microprocessor speed control sequence

Ensure that the microprocessors are properly installed. If the problem persists,

 

SPEED

failure.

replace the faulty microprocessor(s) (see "Microprocessors").

E0F04

POST DMA

DMA initialization failure; DMA page

Ensure that the memory modules are properly installed. If the problem persists,

 

INIT

register write/read failure.

replace the faulty memory module(s) (see "Memory Modules").

 

 

 

 

E0F04

POST DMA REG

Faulty system board.

Replace the system board (see "System Board").

 

 

 

 

E0F04

POST KYB

Faulty keyboard controller; faulty system

Replace the system board (see "System Board").

 

CNTRL

board.

 

E0F04

POST MEM

Main-memory refresh verification failure.

Ensure that the memory modules are properly installed. If the problem persists,

 

RFSH

 

replace the faulty memory module(s) (see "Memory Modules").

 

 

 

 

E0F04

POST PIC REG

Master or slave PIC register test failure.

Replace the system board (see "System Board").

 

 

 

 

E0F04

POST SHADOW

BIOS-shadowing failure.

Ensure that the memory modules are properly installed. If the problem persists,

 

 

 

replace the faulty memory module(s) (see "Memory Modules").

E0F04

POST SHD

Shutdown test failure.

 

 

TEST

 

 

 

 

 

 

E0F04

POST SIO

Super I/O chip failure; faulty system

Replace the system board (see "System Board").

 

 

board.

 

 

 

 

 

E0F04

POST TIMER

Programmable interval timer test failure;

Replace the system board (see "System Board").

 

 

faulty system board.

 

E0F0B

POST ROM

Faulty or improperly installed expansion

Ensure that the expansion cards are properly installed. If the problem persists,

 

CHKSUM

card.

replace the faulty expansion card(s) (see "Expansion Cards").

E0F0C

VID MATCH

Specified microprocessor is faulty,

Ensure that the microprocessors are properly installed. If the problem persists,

 

CPU n

unsupported, improperly installed, or

replace the faulty microprocessor(s) (see "Microprocessors").

 

 

missing.

 

E10F3

LOG DISABLE

BIOS disabled logging errors.

Check the SEL for details on the errors.

 

BIOS

 

 

E13F2

IO CHANNEL

Faulty or improperly installed expansion

Ensure that the expansion cards are properly installed. If the problem persists,

 

CHECK

card; faulty system board.

replace the faulty expansion card(s) (see "Expansion Cards"). If the problem persists,

 

 

 

replace the system board (see "System Board").

E13F4

PCI PARITY

 

 

 

 

 

 

 

E13F5

PCI SYSTEM

 

 

 

 

 

 

E13F8

CPU BUS INIT

Faulty or improperly installed

Ensure that the microprocessors are properly installed. If the problem persists,

 

 

microprocessor or system board.

replace the faulty microprocessor(s) (see "Microprocessors"). If the problem persists,

 

 

 

replace the system board (see "System Board").

 

 

 

 

E13F8

CPU BUS

Faulty system board.

Replace the system board (see "System Board").

 

PARITY

 

 

 

 

 

 

E13F8

CPU MCKERR

Machine check error; faulty or improperly

Ensure that the microprocessors are properly installed. If the problem persists,

 

 

installed microprocessor; faulty system

replace the faulty microprocessor(s) (see "Microprocessors"). If the problem persists,

 

 

board.

replace the system board (see "System Board").

 

 

 

 

E13F8

HOST BUS

Faulty system board.

Replace the system board (see "System Board").

 

 

 

 

E13F8

HOST TO PCI

 

 

 

BUS

 

 

 

 

 

 

E13F8

MEM

Faulty or improperly installed memory

Ensure that the memory modules are properly installed. If the problem persists,

 

CONTROLLER

module; faulty system board.

replace the faulty memory module(s) (see "Memory Modules"). If the problem

 

 

 

persists, replace the system board (see "System Board").

E1580

POWER

Faulty system board.

Replace the system board (see "System Board").

 

CONTROL

 

 

 

 

 

 

E20F1

OS HANG

Operating system watchdog timer timed

Restart your system. If the problem persists, see your operating system

 

 

out.

documentation.

 

 

 

 

 

 

 

 

Page 12
Image 12
Dell 2650 manual See Memory Modules