Table
Warning Message | Corrective Action |
|
|
WARNING: Found | This warning message appears when at least one virtual disk is |
virtual disks | in a Failed state and Pause if Failed is set to ON at the |
that are | PERC Virtual Disk Management utility. |
Failed | The following message appears after the warning is displayed: |
| |
| to enter setup |
| Press <Enter> to allow the operating system to continue its |
| boot, or press <Ctrl><R> to enter into the PERC Virtual Disk |
| Management utility to investigate the cause of the Failed virtual |
| disk. |
| NOTE: A boot virtual disk that is in a Failed state prevents the |
| operating system from booting. |
| To investigate the cause, check for the following: |
| • Determine if a single or multiple physical disks in a non- |
| redundant virtual disk have failed. If "yes," data is lost. Recover |
| the lost data from a backup storage source. |
| • Determine if two or more physical disks in a redundant virtual |
| disk have failed. If "yes," data is lost. Recover the lost data |
| from a backup storage source. |
| NOTE: For a RAID 10, if a single physical disk fails in each |
| mirrored set, the redundant virtual disk goes to a Degraded status |
| but data is not lost. If two physical disks fail in one of the mirrored |
| sets, the redundant virtual disk goes to a Failed status and data is |
| lost. |
66