Table 7-4. Warning Messages: Dell Inc. PERC S100 or S300 Adapter BIOS (continued)

Warning Message

Corrective Action

 

 

WARNING: Found

This warning message appears when at least one virtual disk is

virtual disks

in a Failed state and Pause if Failed is set to ON at the

that are

PERC Virtual Disk Management utility.

Failed

The following message appears after the warning is displayed:

 

--- Press <Enter> to continue, or <Ctrl><R>

 

to enter setup ---

 

Press <Enter> to allow the operating system to continue its

 

boot, or press <Ctrl><R> to enter into the PERC Virtual Disk

 

Management utility to investigate the cause of the Failed virtual

 

disk.

 

NOTE: A boot virtual disk that is in a Failed state prevents the

 

operating system from booting.

 

To investigate the cause, check for the following:

 

• Determine if a single or multiple physical disks in a non-

 

redundant virtual disk have failed. If "yes," data is lost. Recover

 

the lost data from a backup storage source.

 

• Determine if two or more physical disks in a redundant virtual

 

disk have failed. If "yes," data is lost. Recover the lost data

 

from a backup storage source.

 

NOTE: For a RAID 10, if a single physical disk fails in each

 

mirrored set, the redundant virtual disk goes to a Degraded status

 

but data is not lost. If two physical disks fail in one of the mirrored

 

sets, the redundant virtual disk goes to a Failed status and data is

 

lost.

66

Troubleshooting

Page 66
Image 66
Dell S300, S100 manual Lost