Table 3-1. Features of the PERC S100 controller and PERC S300 controller (continued)

RAID Controller Feature Description

• In a brief warning at the Dell Inc. PERC S100 Controller

BIOS or Dell Inc. PERC S300 Controller BIOS screen, that a virtual disk(s) were found that are Degraded and/or Failed. This alerts the user to the failed physical disk(s).

• At Dell OpenManage Server Administrator Storage Management.

• With a bi-color Status LED on each physical disk. The green element of the Status LED is off, while the amber element flashes on and off.

 

NOTE: The Status LED applies only to systems with a PERC S300

 

adapter and a backplane that has removable physical disks.

 

NOTE: PERC S100 adapters support HDD physical disks of

 

capacity 2 TB and greater. Current and upcoming releases of

 

PERC S300 adapters will only support upto 2 TB HDD physical

 

disks .

 

 

Physical disk

Hot-swap (hot-plug) capability is the manual substitution of

hot-swapping

a physical disk for another one while the host system is

(hot-swap capability)

powered on.

 

If a system supports hot-swapping, physical disks can be

 

plugged into a system’s backplane while the controller is

 

operating, without causing the controller to reset.

 

CAUTION: A physical disk can be hot-swapped from a system

 

only if the system has a PERC S300 adapter and a backplane

 

that supports hot-swapping.

 

NOTE: If a system’s physical disks are accessible only when the

 

system’s cover is removed, the physical disks cannot be hot-

 

swapped. The physical disks must be located on the backplane

 

(behind the removable front panel) and accessible externally.

 

NOTE: When replacing physical disks in a virtual disk that has

 

already been created, make sure that SAS HDD physical disks

 

are replaced with SAS HDD physical disks, that SATA HDD

 

physical disks are replaced with SATA HDD physical disks, and

 

that SATA SSD physical disks are replaced with SATA SSD

 

physical disks.

 

NOTE: When hot-swapping a physical disk, make sure that the

 

new disk is of equal or greater capacity to the physical disk that

 

is being replaced.

Features

25

Page 25
Image 25
Dell S100, S300 manual Disks, That supports hot-swapping