Features
General Features
The features of the Dell PowerEdge RAID Controller (PERC) S100 and PERC S300 adapter are described in Table
NOTE: BAS, BGI, CC and OCE run only on the operating system.
Table
RAID Controller Feature | Description |
|
|
Automatic virtual disk | Rebuilds a redundant virtual disk automatically when a |
rebuild | failure is detected, if a hot spare is assigned for this capability. |
|
|
Background Array | Verifies and corrects correctable media errors on mirror, |
Scan (BAS) | volume, or parity data for virtual disks. BAS starts |
| automatically after a Virtual Disk is created while in the OS. |
|
|
Background virtual | The background initialization of a redundant virtual disk |
disk initialization | creates the parity data that allows the virtual disk to maintain |
(BGI) | its redundant data and survive a physical disk failure. |
| Because background initialization helps the controller to |
| identify and correct problems that might occur with the |
| redundant data at a later time, background initialization is |
| similar to a consistency check. |
| Background initialization allows a redundant virtual disk to |
| be used immediately. Data is lost if a physical disk fails before |
| the completion of a BGI. |
| NOTE: Although a BGI is |
| Disk Management utility, the PERC S100 adapter/PERC S300 |
| adapter drivers must be loaded before the BGI runs. |
| NOTE: Unless mentioned otherwise, the term PERC Virtual Disk |
| Management utility refers to both the PERC S100 Virtual Disk |
| Management utility and the PERC S300 Virtual Disk |
| Management utility. |