Table 1-6. System Messages
System Message | Corrective Action |
|
|
ROM bad checksum = address | Expansion card improperly installed or |
| faulty |
Sector not found | Defective sectors on diskette or |
| drive |
Seek error | Defective sectors on diskette or |
| drive |
Seek operation failed | Faulty diskette or |
Shutdown failure | Defective system board |
Spare bank enabled | DIMM sparing has been enabled |
The amount of system memory | DIMMs have been added or removed |
has changed |
|
Defective battery or faulty chip | |
Incorrect Time or Date settings or | |
run SETUP program | defective system battery |
Timer chip counter 2 failed | Defective system board |
Unexpected interrupt in | Improperly seated DIMMs or faulty |
protected mode | keyboard/mouse controller chip |
Unsupported CPU combination | The installed processors cannot be |
| installed at the same time. |
Unsupported CPU stepping | Invalid processor stepping is detected |
detected |
|
Unsupported DIMM detected in the RAID DIMM slot!
Utility partition not available
Write fault
Write fault on selected drive
BIOS Update Attempt Failed
Warning! No micro code update loaded for processor n
DIMM installed in RAID DIMM slot is not supported.
Utility partition is not available on the hard disk
Faulty diskette or
BIOS remote update failed
Micro code update failed
38