The following table describes the profile commands:

AT&F Use Factory Settings in Current P rofile. Restores and loads all settings in the current
profile with the original factory settings. Previously configured ISDN commands, stored
telephone numbers, and the rate adaption control values are retained; all other settings
are replaced.
AT&V View Current and Stored Profiles. Displays the current and stored profiles as well as
stored telephone numbers in your DIVAT/A.
AT&W n Save Settings as Profile n. Writes storable parameters of current profile in memory as
stored profile n. Use when you are satisfied with your current configuration settings
and want to save them to a specific stored profile n.
AT&Y n Set Powerup Profile. Designates stored profile n as the powerup profile. Use to load
your desired stored profile the next time your DIVAT/A is powered up.
AT>F Use Factory Settings in All Profiles. Restores all stored profiles and the current profile
to the original factory settings. Reverts the powerup profile to number 0. Use when you
need to reset the device to its original factory settings.
Warning: All previous user-defined settings are lost.
AT>F C Reset Current Profile and Telephone Numbers. Resets the current profile and
telephone numbers to the default factory settings.
AT>V C View Current Profile. Presents a screen display of the current profile settings on your
DIVAT/A.
AT>V CC View Call and COM Port Parameters. Displays the Call and COM Port dynamic
parameters.
AT>V CD View Dynamic Parameters. Displays all dynamic parameters (Call, COM, V.120, V.110.
PPP, MLPPP).
AT>V CP View Protocol Parameters. Displays the protocol paramete rs (V.120, V.110, PPP,
MLPPP).
AT>V CS View Static Parameters. Displays all static parameters (ISDN, Rate Adaptation).
AT>V Pn View Stored Profile. Presents a screen display of the desired stored profile, where n is
the number of the stored profile (0,1,2) you want to view.
AT>Z Restart DIVAT/A Using Powerup Pr ofile. Restarts your DIVAT/A using the powerup
profile. Use anytime you want to load the powerup profile.
ATZn Restart DIVAT/A Using Profile n. Restarts your DIVAT/A using stored profile n. Use
after changing a static parameter.