Profile Commands
The following table describes the profile commands:
| AT&F | Use Factory Settings in Current Profile. Restores and loads all settings in the current | 
| 
 | profile with the original factory settings. Previously configured ISDN commands, stored | 
| 
 | telephone numbers, and the rate adaption control values are retained; all other settings | 
| 
 | are replaced. | 
| 
 | 
 | 
| AT&V | View Current and Stored Profiles. Displays the current and stored profiles as well as | 
| 
 | stored telephone numbers in your DIVA T/A. | 
| 
 | 
 | 
| AT&Wn | Save Settings as Profile n. Writes storable parameters of current profile in memory as | 
| 
 | stored profile n. Use when you are satisfied with your current configuration settings | 
| 
 | and want to save them to a specific stored profile n. | 
| 
 | 
 | 
| AT&Yn | Set Powerup Profile. Designates stored profile n as the powerup profile. Use to load | 
| 
 | your desired stored profile the next time your DIVA T/A is powered up. | 
| 
 | 
 | 
| AT>F | Use Factory Settings in All Profiles. Restores all stored profiles and the current profile | 
| 
 | to the original factory settings. Reverts the powerup profile to number 0. Use when you | 
| 
 | need to reset the device to its original factory settings. | 
| 
 | Warning: All previous  | 
| 
 | 
 | 
| AT>FC | Reset Current Profile andTelephone Numbers . Resets the current profile and | 
| 
 | telephone numbers to the default factory settings. | 
| 
 | 
 | 
| AT>VC | View Current Profile. Presents a screen display of the current profile settings on your | 
| 
 | DIVA T/A. | 
| 
 | 
 | 
| AT>VCC | View Call and COM Port Parameters. Displays the Call and COM Port dynamic | 
| 
 | parameters. | 
| 
 | 
 | 
| AT>VCD | View Dynamic Parameters. Displays all dynamic parameters (Call, COM, V.120, V.110. | 
| 
 | PPP, MLPPP). | 
| 
 | 
 | 
| AT>VCP | View Protocol Parameters. Displays the protocol parameters (V.120, V.110, PPP, | 
| 
 | MLPPP). | 
| 
 | 
 | 
| AT>VCS | View Static Parameters. Displays all static parameters (ISDN, Rate Adaptation). | 
| 
 | 
 | 
| AT>VPn | View Stored Profile. Presents a screen display of the desired stored profile, where n is | 
| 
 | the number of the stored profile (0,1,2) you want to view. | 
| 
 | 
 | 
| AT>Z | Restart DIVA T/A Using Powerup Profile. Restarts your DIVA T/A using the powerup | 
| 
 | profile. Use anytime you want to load the powerup profile. | 
| 
 | 
 | 
| ATZn | Restart DIVA T/A Using Profile n. Restarts your DIVA T/A using stored profile n. Use | 
| 
 | after changing a static parameter. | 
| 
 | 
 | 