Multilink PPP Commands

Endpoint Discriminator Class/Address

The following table describes the list of classes and permitted addresses for certain MultiLink PPP commands.

Class

Description

Address Format

0

Null Class

No address is used.

 

 

 

1

Locally Assigned

Uses a hexadecimal format with a maximum length of 40

 

Address

characters.

 

 

Valid characters: “0-9, a-f”. The number of digits must be even (ex.

 

 

AT%M3=b3c665ac11).

 

 

 

2

Internet Protocol (IP)

Uses a numerical format with a maximum length of 15 characters.

 

Address

Valid characters: “0-9” (ex. AT%M4=192.219.23.100).

 

 

 

 

 

3

IEEE 802.1 Globally

Uses a hexadecimal format with an exact length of 12 characters.

 

Assigned MAC Address

Valid characters: “0-9, a-f” (ex. AT%M3=b3c665ac1fff).

 

 

 

 

 

4

PPP Magic-Number

Uses a hexadecimal format with a maximum length of 40

 

Block

characters, and the length must be a multiple of 8.

 

 

Valid characters: “0-9, a-f” (ex. AT%M3=b3c665acffff0001).

 

 

 

5

Public Switched

Uses a normal telephone number with a maximum length of 15.

 

Network Directory

Valid characters are “0-9, *, #”.

 

Number

 

 

 

 

255

Accept Any Remote

No address is used. This class is valid only for remote endpoint

 

Endpoint Discriminator

discriminators (EPDs), and is used to accept any remote EPDs

 

 

received that are all part of the same bundle.

 

 

 

DIVA T/A ISDN Modem Reference Guide Page 48

Page 48
Image 48
Eicon Networks DIVA T/A ISDN Modem manual Endpoint Discriminator Class/Address, AT%M3=b3c665ac11, Internet Protocol IP