S-Register Commands

The following five commands apply to S-Registers, which are described further below.

ATSn=v

S-Register n to Value v. Sets S-Register n to the value v.

 

 

ATSn

Establishes S-Register n as the Selected Register. Sets S-Register n as the last

 

register accessed, where n is the number identifying the S-Register. For example,

 

ATS7 establishes S7 as the last accessed register.

 

 

ATSn?

Reports the Value of S-Register n. Reports the last value stored into S-Register n. If

 

n is omitted, the last S-Register is accessed.

 

 

AT=n

Last Accessed S-Register to Value v. Use this command to set the last accessed

 

S-Register to the new value n.

 

 

AT?

View Last Accessed S-Register. Displays the contents of the “selected” S-Register.

 

The “selected” S-Register is the last S-Register that was accessed using an S-Register

 

command, or selected with the ATSn command.

 

 

S Register Parameters

Register

Description

S0

Enable/Disable Auto-answer. Specifies whether auto answer is enabled or disabled.

 

Setting a value other than “0” instructs the DIVA T/A to auto-answer after n rings. A

 

value of “0” instructs the DIVA T/A to disable the auto-answer mode. Type: Storable.

 

v=0

No auto answer (default).

 

v=1-255 Answers after this number of rings

 

 

S1

View Ring Count. Specifies number of rings.

 

Default: 0. Type: Non-Storable.

 

Note: This register is reset to 0 if 8 seconds elapse since receipt of the previous ring.

 

 

S2

Escape Sequence Character. Specifies the character used to escape from the data

 

mode and return to the AT command mode.

 

Range: 0 to 255. Type: Storable.

 

Default: ASCII 043, translates into the “+” character.

 

 

S3

Carriage Return Character. Specifies the character that the AT command processor

 

uses to detect the end of a command line in both the receive and transmit directions.

 

Range: 0 to 127. Type: Non-Storable.

 

Default: ASCII 013 which translates into the carriage return character.

 

 

S4

Line Feed Character. Specifies the character that the AT command processor uses to

 

indicate the end of each status message.

 

Range: 0 to 127. Type: Non-Storable.

 

Default: ASCII 010 line feed.

 

 

S5

Backspace Character. Specifies the backspace character used for command line

 

editing.

 

 

Default: ASCII 008 (backspace). Type: Non-Storable.

 

 

 

DIVA T/A ISDN Modem Reference Guide Page 57

Page 57
Image 57
Eicon Networks DIVA T/A ISDN Modem manual Register Commands, At?