2

Power Requirements

Table 2-5:

Power Requirements

S E T U P

Operational Checks

Be sure your power supply is sufficient for the board. The combined power (3.3 volts and 5 volts) for a CC1000dm is 27 watts. Table 2-5lists the specific power requirements for the CC1000dm. Please contact Artesyn Technical Support at 1http://www.arte- syncp.com/support on the internet or send E-mail to support@artesyncp.com if you have specific questions regarding the board’s power requirements.

 

 

Typical Current

 

Voltage:

Range:

(amps):

Usage:

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

+3.3 V

+5/-3%

1.0

Board logic

 

 

 

 

+5 V

+5/-3%

0.4

Board logic

 

 

 

 

+12 V

±5%

0.5

PMC slot power

 

 

 

 

–12 V

±5%

0.5

PMC slot power

 

 

 

 

VIO

±5%

0.75

PCI signaling for board logic

 

 

 

 

Environmental Considerations

Table 2-6:

Environmental Requirements

As with any printed circuit board, be sure that air flow to the board is adequate. Chassis constraints and other factors greatly affect the air flow rate. The environmental require- ments are as follows:.

Voltage:

Usage:

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operating Temperature

0 to +55O Centigrade, ambient (at board)

Relative Humidity

Not to exceed 95% (non-condensing)

 

 

Storage Temperature

-40 to +85O Centigrade, ambient

Shock and Vibration

NEBS Level 3 compliant

 

 

.O.P. E. R. .A. T. I.O. .N.A. .L. .C.H. E. .C.K. S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

All products are tested before they are shipped from the factory. When you receive your CC1000dm, follow these steps to assure yourself that the system is operational:

1Visually inspect the board for components that could have loosened during shipment.

2Verify that the front panel is secure.

3By default, the CC1000dm carrier card is configured to support 3.3 V I/O operation on the secondary bus. Please be sure to select the appropriate voltage for your application.

2-10CC1000dm User’s Manual

10004281-02

Page 28
Image 28
Emerson CC1000DM Power Requirements, Environmental Considerations, Operational Checks, Typical Current Voltage Range Amps