Purging with Dry Gas

Section 4 • Operation

Purging with Dry Gas

NOTICE

Purging is recommended if the compressor will be inactive for 12 hours or more. For additional long term storage information, refer to Long Term Storage Recommendations in Section 3.

PREPARATION

WARNING

When working with LFG, NG or other dangerous or flammable gases, ensure there are adequate ventilation and vapor detectors. Refer to national fire and building codes. Failure to comply may result in serious injury or death.

WARNING

When working pressured systems, always wear safety glasses and/or face shield. Failure to comply may result in serious injury.

To purge the compressor unit using a dry gas (i.e. methane), a purge line must be installed. If there is not enough purge pressure, connect purge line to a lower pressure line or to atmosphere. The purge line, associated valves and gauges are not provided from the

factory and must be installed by the customer.

1.Refer to Figure 4-10 for recommended purge line design.

2.Press “Stop” button to stop compressor unit, see Figure 4-11.

3.If equipped with equalizing solenoid, allow pres- sure in compressor unit to equalize to suction pres- sure, see Figure 4-12.

4.If equipped with manual suction bypass valve and it is not open, open suction bypass valve. Allow pressure in compressor unit to equalize to suction pressure.

5.Close suction and discharge shut-off valves to isolate the compressor unit from house system. Lockout/tagout valves.

To Lower Pressure Line or

PI

Pressure Indicator

Atmosphere. See NOTICE.

002

Shut-off Valve

 

Check Valve

 

Shut-off Valve

 

 

 

 

 

 

Drain Valve

 

 

 

 

PI

 

 

002

 

PURGE LINE

SUCTION INLET

 

DRAIN

 

 

 

 

PRESSURE EQUALIZING LINE

 

OIL RETURN LINE

 

 

COALESCING

FG

 

 

001

 

 

 

 

 

 

DISCHARGE OUTLET

 

 

 

 

 

TE

 

 

 

 

 

 

 

002

 

 

OIL CHARGE

 

 

 

 

REMOTE

 

PT

001

004

 

 

 

 

001

TE

TE

 

 

 

 

 

 

 

 

 

 

 

BLEED

 

 

 

 

OIL COOLER

 

MOTOR

 

 

 

COMPRESSOR

TE

 

 

 

 

 

 

007

VENT

 

 

 

PT

 

 

 

 

 

 

 

002

 

 

QE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

007

 

 

 

 

BLEED

 

 

 

 

 

 

 

OIL SEPARATOR

 

 

TE

 

 

 

DRAIN

003

 

LG

 

 

 

 

 

 

 

001

 

 

 

 

 

 

 

 

LG

 

 

 

 

 

 

 

002

 

 

 

 

 

TE

1000W

1000W

QE

1000W

 

 

 

QE

QE

 

 

 

 

005

101

102

103

DRAIN

 

 

 

 

 

 

 

 

 

 

Figure 4-10. Customer Purge Line

VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG