Table 3-2. Maximum Allowable Flange Loads

Section 3 • Installation

Table 3-2. Maximum Allowable Flange Loads

Nozzle Dia. (in.)

Fz (lbf)

Fy (lbf)

Fx (ft-lbf)

Mzz (ft-lbf)

Myy (ft-lbf)

Mxx (ft-lbf)

 

 

 

 

 

 

 

4

400

400

400

300

300

300

 

 

 

 

 

 

 

6

600

600

600

500

500

500

 

 

 

 

 

 

 

8

900

900

900

1000

1000

1000

 

 

 

 

 

 

 

10

1200

1200

1200

1200

1200

1200

 

 

 

 

 

 

 

12

1500

1500

1500

1500

1500

1500

 

 

 

 

 

 

 

14

2000

2000

2000

2000

2000

2000

 

 

 

 

 

 

 

 

 

HANGER

CUSTOMER SUPPORTS

5 PIPE

DISCHARGE

WHEN CHECK VALVE

DIAMETERS

IS MOUNTED HERE

 

LINE

5 PIPE

 

 

 

 

DIAMETERS

3-4 PIPE

5 PIPE

 

 

DIAMETERS

DIAMETERS

 

 

 

 

 

CHECK

 

 

VALVE

 

 

SUCTION

 

CUSTOMER

LINE

 

SUPPORT

Y

 

 

 

Z

X

X

Z

CUSTOMER

SUPPORT

Y

Figure 3-9. Maximum Allowable Flange Loads

VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG

3 – 11

Page 31
Image 31
Emerson VSG, VSSG 2. Maximum Allowable Flange Loads, Installation, Nozzle Dia. in, Fz lbf, Fy lbf, Fx ft-lbf, Mzz ft-lbf