Table 6-3. Troubleshooting Guide - General Problems & Solutions (3 of 3)

Section 6 • Troubleshooting

Table 6-3. Troubleshooting Guide - General Problems & Solutions (3 of 3)

Problem

Solution

High Amp Draw

• Check Main Motor Amps scaling and PLC.

 

 

 

• Check that unit is leveled and secured to mounting pad or floor.

 

• Check supported pipes (i.e. suction and discharge pipe) and make sure they

Vibration

are adequately supported.

 

• Check for loose bolts and nuts.

 

• Check condition of compressor and motor (i.e. alignments)

 

 

Excessive Motor Backspin

• If there is more than normal motor backspin at shutdown, check suction

check valve for proper operation.

 

 

 

VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG