Emerson VSSG, VSG manual Slide Valve Actuator Assembly Replacement, 28. Roller Bearing Assembly

Models: VSG

1 106
Download 106 pages 24.52 Kb
Page 86
Image 86
Figure 5-28. Roller Bearing Assembly

Section 5 • Maintenance/Service

The bevel on the snap ring must face away from the roller bearing.

Figure 5-28. Roller Bearing Assembly

Slide Valve Actuator Assembly Replacement

To replace slide valve actuator assembly, proceed with the following steps:

REMOVAL

WARNING

At shutdown, open any other valves that may trap liquids to prevent serious injury and/or damage to equipment.

WARNING

Follow local lockout/tagout procedure. Failure to comply may result in serious injury, death and/or damage to equipment.

NOTE

This procedure is applicable to both capacity and

volume slide valve actuator assemblies.

1.Shut down the compressor unit, refer to Stopping/

Restarting procedure in Section 4.

2.Turn disconnect switches to the OFF position for the compressor unit and oil pump motor starter, if equipped.

3.Allow compressor, motor and surrounding compo- nents to cool prior to servicing.

4.Disconnect connectors from actuator.

NOTE

Note orientation of components to aid in installation.

5.Remove screws and lock washers securing actuator assembly to actuator mount.

6.Remove actuator assembly from actuator mount.

INSTALLATION

CAUTION

When installing the slide valve actuator assembly, loosen locking collar down the shaft. Do not use a screwdriver to pry locking collar into position.

7.Position actuator assembly on mount as noted in removal.

8.Install lock washers and screws to secure actuator assembly to actuator mount.

9.Tighten screws, see Appendix A.

10.Connect connectors to actuator assembly.

11.Calibrate actuator assembly, see Slide Valve Calibration procedure in Section 4.

5 – 28

VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG

Page 86
Image 86
Emerson VSSG, VSG manual Slide Valve Actuator Assembly Replacement, 28. Roller Bearing Assembly, Maintenance/Service