Section 5 • Maintenance/Service
necessary. It is preferable to shim the gate rotor blade looser rather than tighter against the shelf.
14. Once the clearance is set remove the spindle. Install new
15. Install side covers with new gaskets. Tighten bolts, see Appendix A. The unit can now be evacuated and leak checked.
Check for
gate rotor blade and partition.
Figure 5-23. Gate Rotor and Shelf Clearance
Figure 5-22. Gate Rotor Thrust Bearing
VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG | 5 – 25 |