Troubleshooting Checklist

Troubleshooting Checklist

If the 2G4072‐52 is not working properly, refer to Table 4‐2 for a checklist of problems, possible causes, and recommended actions to resolve the problem.

Table 4-2 Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

 

 

 

All LEDs are

Loss of power.

Ensure the 2G4072-52 was installed properly according to

OFF.

 

the installation instructions in Chapter 3, and that the

 

 

chassis has power.

 

 

 

No Local

Incorrect terminal setup.

Refer to the Enterasys Matrix N Standalone Series

Management

 

Configuration Guide for proper setup procedures.

Password

 

 

Improper console cable pinouts.

Refer to Appendix A for proper COM port pinouts.

screen.

 

 

 

Corrupt firmware image or

If possible, attempt to download the image to the

 

hardware fault.

2G4072-52 again. Refer to Appendix B for instructions to

 

 

clear NVRAM.

 

 

 

Cannot navigate

Improper username/ password

If the username/password combination has been forgotten,

beyond

combination entered.

refer to Appendix B for instructions on how to set the mode

Password

 

switch to reset the username/password combination to the

screen.

 

default values.

 

 

 

Cannot contact

IP address not assigned.

Refer to the Enterasys Matrix N Standalone Series

the 2G4072-52

 

Configuration Guide for the IP address assignment

through in-band

 

procedure.

management.

 

 

Port is disabled.

Enable port. See Enterasys Matrix N Standalone Series

 

 

 

Configuration Guide for instructions to enable/disable

 

 

ports.

Host Port policy and/or management VLAN is incorrectly configured, or not configured.

Verify that a management VLAN exists and that it is associated with the Host Port.

Refer to the Enterasys Matrix N Standalone Series Configuration Guide for information about Host Port and management VLAN configuration.

No link to device.

Verify that all network connections between the network

 

management station and the 2G4072-52 are valid and

 

operating.

 

If the problem continues, contact Enterasys Networks for

 

technical support.

 

 

4-4 Troubleshooting

Page 50
Image 50