Overview of Shutdown Procedure

Table 4-2 Troubleshooting Checklist (continued)

 

 

 

Problem

Possible Cause

Recommended Action

 

 

 

Port(s) goes into

Loop condition detected.

Verify that Spanning Tree is enabled. Refer to the

standby for no

 

Enterasys Matrix N Standalone Series Configuration Guide

apparent reason.

 

for the instructions to set the type of STA.

 

 

Review the network design and delete loops.

 

 

If the problem continues, contact technical support.

 

 

 

User parameters

Position of Mode switch (7),

Reenter the lost parameters as necessary. Refer to the

(IP address,

Persistent Data Reset, was

Enterasys Matrix N Standalone Series Configuration Guide

device and

changed sometime before either

for the instructions to configure the device.

device name,

cycling power or pressing the

If the problem persists, contact Enterasys Networks for

etc.) were lost

RESET button, causing the user-

technical support.

when the

entered parameters to reset to

 

2G4072-52

factory default settings.

 

power was

Clear Persistent Data that was

 

cycled, the

set through Local Management.

RESET button

 

was pressed.

 

 

 

Overview of Shutdown Procedure

You can shut down a 2G4072‐52 in an operating system using the RESET button shown in Figure 4‐2. There are two procedures to shut down a 2G4072‐52:

Recommended shutdown procedure (page 4‐6)

Last resort shutdown procedure (not recommended) (page 4‐6)