| Overview of Shutdown Procedure | |
Table | |||
|
|
| |
Problem | Possible Cause | Recommended Action | |
|
|
| |
Port(s) goes into | Loop condition detected. | Verify that Spanning Tree is enabled. Refer to the | |
standby for no |
| Enterasys Matrix N Standalone Series Configuration Guide | |
apparent reason. |
| for the instructions to set the type of STA. | |
|
| Review the network design and delete loops. | |
|
| If the problem continues, contact technical support. | |
|
|
| |
User parameters | Position of Mode switch (7), | Reenter the lost parameters as necessary. Refer to the | |
(IP address, | Persistent Data Reset, was | Enterasys Matrix N Standalone Series Configuration Guide | |
device and | changed sometime before either | for the instructions to configure the device. | |
device name, | cycling power or pressing the | If the problem persists, contact Enterasys Networks for | |
etc.) were lost | RESET button, causing the user- | ||
technical support. | |||
when the | entered parameters to reset to | ||
| |||
factory default settings. |
| ||
power was | Clear Persistent Data that was |
|
cycled, the | set through Local Management. | |
RESET button | ||
| ||
was pressed. |
| |
|
|
Overview of Shutdown Procedure
You can shut down a 2G4072‐52 in an operating system using the RESET button shown in Figure 4‐2. There are two procedures to shut down a 2G4072‐52:
•Recommended shutdown procedure (page 4‐6)
•Last resort shutdown procedure (not recommended) (page 4‐6)
N Standalone Series Installation Guide